The Circuit Breaker, cataloged under National Stock Number 5925-01-096-4664, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Federal Specifications Promulgated by General Services Administration Washington DC. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 2 commercial cross-references from 1 manufacturer, enabling identification through both NSN and commercial part number lookups. 11 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-096-4664 |
| Primary Part Number | W-C-375/18 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | Federal Specifications Promulgated by General Services Administration Washington DC |
| Status | ACTIVE |
| Test Data Document | 81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Actuator Position Designation | AT POLE TWO |
| Terminal Type and Quantity | 6 COMPRESSION |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Actuator Function | TRIP-RESET |
| Material | PLASTIC CASE |
| Operating Voltage Type and Rating Per Pole in Volts | 480.0 AC ALL LOCATIONS |
| Reset Method | MANUAL |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Trip Release Ambient Temp Rating | 40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Trip Delay Time in Seconds Per Rated Continuous Current | 120.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Specification/standard Data | 81348-W-C-375/18 GOVERNMENT SPECIFICATION |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 14000.0 AC ALL LOCATIONS |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT |
| Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S) |
| Center to Center Distance Between Terminals Parallel to Width | 1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM IN |
| Pole Quantity | 3 |
| Center to Center Distance Between Terminals Parallel to Length | 5.366 INCHES MINIMUM AND 5.386 INCHES MAXIMUM IN |
| Boss Height | 0.115 INCHES MINIMUM AND 0.135 INCHES MAXIMUM IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM IN |
| Unthreaded Mounting Hole Diameter | 0.188 INCHES NOMINAL IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 4.490 INCHES MINIMUM AND 4.510 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| W-C-375/18 | Federal Specifications Promulgated by General Services Administration Washington DC (USA) |
| WC375/18-001 | Federal Specifications Promulgated by General Services Administration Washington DC (USA) |
NSN 5925-01-096-4664 is a Circuit Breaker, manufactured by Federal Specifications Promulgated by General Services Administration Washington DC, classified under FSC 5925 (No Item Name Available). Status: active.
NSN 5925-01-096-4664 has 2 cross-referenced part numbers: W-C-375/18 (Federal Specifications Promulgated by General Services Administration Washington DC), WC375/18-001 (Federal Specifications Promulgated by General Services Administration Washington DC).
There are 11 known substitutes for 5925-01-096-4664: 5925-00-211-1900, 5925-00-232-2840, 5925-00-236-9000 and 8 more. Verify interchangeability with system specifications before substitution.
Key specifications for W-C-375/18: Test Data Document: 81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).; Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 125.0 ALL LOCATIONS; Actuator Position Designation: AT POLE TWO; Terminal Type and Quantity: 6 COMPRESSION. 30 total characteristics are documented in the Federal Logistics Information System.