The TRANSFORMER,POWER is a the manufacturer industrial component. Key specifications include material: STEEL, body_length: 0.590 INCHES NOMINAL IN, overall_depth: 10.500 INCHES NOMINAL IN, overall_width: 7.000 INCHES NOMINAL IN, cooling_method: SELF-COOLED, inclosure_type: FULLY INCLOSED. This product is currently in active production with full OEM support.
This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5950-00-626-9449, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| material | STEEL |
| body_length | 0.590 INCHES NOMINAL IN |
| overall_depth | 10.500 INCHES NOMINAL IN |
| overall_width | 7.000 INCHES NOMINAL IN |
| cooling_method | SELF-COOLED |
| inclosure_type | FULLY INCLOSED |
| overall_height | 3.250 INCHES NOMINAL IN |
| mounting_method | THREADED HOLE(S) SINGLE GROUP |
| frequency_rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| style_designator | OPEN FLANGED ENDS |
| surface_treatment | ZINC |
| material_thickness | 0.560 INCHES NOMINAL IN |
| NSN | 5950-00-626-9449 |
| THREAD QUANTITY PER INCH | 40 SINGLE GROUP |
| WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MINIMUM AND 175.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 19.50 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 36.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| COOLING METHOD | SELF-COOLED |
| INCLOSURE TYPE | FULLY INCLOSED |