The Circuit Breaker, cataloged under National Stock Number 5925-01-092-9694, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M. Government technical data includes 25 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 6 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 5925-01-092-9694 |
| Primary Part Number | M13516/7BII-90 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| Status | CANCELLED |
| Body Style | SINGLE POLE TYPE |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Trip Delay Time in Seconds Per Rated Continuous Current | 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Specification/standard Data | 58536-AA55571/07-008 GOVERNMENT SPECIFICATION |
| Material | PLASTIC CASE |
| Trip Release Method | THERMAL SINGLE LOCATION |
| Terminal Type and Quantity | 2 THREADED STUD |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 575.0 DC SINGLE LOCATION |
| Trip Release Ambient Temp Rating | 25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 28.0 DC SINGLE LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 90.0 AMPERES DC SINGLE LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 SINGLE LOCATION |
| Reset Method | AUTOMATIC |
| Inclosure Protection Type for Which Designed | VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 2.000 INCHES MAXIMUM IN |
| Unthreaded Mounting Hole Diameter | 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.406 INCHES NOMINAL IN |
| Fragility Factor | MODERATELY RUGGED |
| Center to Center Distance Between Terminals Parallel to Length | 1.060 INCHES NOMINAL IN |
| Mounting Facility Type and Quantity | 2 UNTHREADED HOLE(S) |
| Body Width | 1.880 INCHES NOMINAL IN |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| M13516/7BII-90 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| MIL-C-13516/7 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| A-A-55571/7 | Federal Commercial Item Description Promulgated by General Services Administration Washington DC (USA) |
| M13516/7-8 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| AA55571/07-008 | Federal Commercial Item Description Promulgated by General Services Administration Washington DC (USA) |
| PDLA-90 | Sensata Technologies, Inc. Div Sensata Attleboro (USA) |
NSN 5925-01-092-9694 is a Circuit Breaker, manufactured by Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M, classified under FSC 5925 (No Item Name Available). Status: cancelled.
NSN 5925-01-092-9694 has 6 cross-referenced part numbers: M13516/7BII-90 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), MIL-C-13516/7 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), A-A-55571/7 (Federal Commercial Item Description Promulgated by General Services Administration Washington DC), M13516/7-8 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), AA55571/07-008 (Federal Commercial Item Description Promulgated by General Services Administration Washington DC) and 1 more.
There are 12 known substitutes for 5925-01-092-9694: 5925-00-173-7634, 5925-00-247-2076, 5925-00-295-5460 and 9 more. Verify interchangeability with system specifications before substitution.
Key specifications for M13516/7BII-90: Body Style: SINGLE POLE TYPE; Overall Length: 3.160 INCHES NOMINAL IN; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Trip Delay Time in Seconds Per Rated Continuous Current: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION. 26 total characteristics are documented in the Federal Logistics Information System.
NSN 5925-01-092-9694 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.