JULY 2026Technical Data Sheet

MS39068-5Circuit Breaker

Military Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M · NSN 5925-00-411-5170 · FSC 5925 · No Item Name Available
Verified by PartsTable
NSN 5925-00-411-5170 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-411-5170. Primary manufacturer part number: MS39068-5.
Features
  • Circuit Breaker — FSC 5925
  • Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps: 575.0 DC SINGLE LOCATION
  • Maximum Continuous Load Current Rating Per Pole: 120.0 AMPERES DC SINGLE LOCATION
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 138.0 SINGLE LOCATION
  • Body Style: SINGLE POLE TYPE
  • Specification/standard Data: 81349--13516/7BII PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Trip Release Method: THERMAL SINGLE LOCATION
Applications
  • Applications requiring Plastic Case construction
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-411-5170, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Military Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M. Government technical data includes 26 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 9 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-411-5170
Primary Part NumberMS39068-5
Item NameCircuit Breaker
FSC / FSG5925 / 59 — No Item Name Available
ManufacturerMilitary Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M
StatusACTIVE
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps575.0 DC SINGLE LOCATION
Maximum Continuous Load Current Rating Per Pole120.0 AMPERES DC SINGLE LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 SINGLE LOCATION
Body StyleSINGLE POLE TYPE
Specification/standard Data81349--13516/7BII PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Trip Release MethodTHERMAL SINGLE LOCATION
Mounting Surface to Terminal End Distance2.000 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Storage TypeGENERAL PURPOSE WAREHOUSE
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S)
Pole Quantity1
Unthreaded Mounting Hole Diameter0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM IN
Center to Center Distance Between Terminals Parallel to Length1.060 INCHES NOMINAL IN
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.406 INCHES NOMINAL IN
Terminal Type and Quantity2 THREADED STUD
Body Width1.880 INCHES NOMINAL IN
MaterialPLASTIC CASE
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Inclosure Protection Type for Which DesignedVIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Test Data Document81349-MIL-C-13516 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Reset MethodAUTOMATIC
Operating Voltage Type and Rating Per Pole in Volts28.0 DC SINGLE LOCATION
Trip Delay Time in Seconds Per Rated Continuous Current8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Verified Substitutes 9
5925-00-247-2076 INTERCHANGEABLE
Circuit Breaker
5925-00-295-5460 INTERCHANGEABLE
Circuit Breaker
5925-00-295-5462 INTERCHANGEABLE
Circuit Breaker
5925-00-420-8561PDLA-40 INTERCHANGEABLE
Circuit Breaker
Sensata Technologies, Inc. Div Sensata Attleboro
5925-00-708-8769 INTERCHANGEABLE
Circuit Breaker
5925-00-775-1717 INTERCHANGEABLE
Circuit Breaker
5925-01-092-9694 INTERCHANGEABLE
Circuit Breaker
5925-01-265-7692 INTERCHANGEABLE
Circuit Breaker
5925-01-429-4554 INTERCHANGEABLE
Circuit Breaker
Cross-Reference Index
Part NumberManufacturer
MS39068-5 Military Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M
M13516/7-10 Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
5925004115170 E.c.a Etablissement Central Des Approvisionnements Des Forces Armees Royales
MIL-C-13516/7 Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
M13516/7BII-120 Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
Related Parts
5925-00-247-2076INTERCHANGEABLE
CIRCUIT BREAKER
5925-00-295-5460INTERCHANGEABLE
CIRCUIT BREAKER
5925-00-295-5462INTERCHANGEABLE
CIRCUIT BREAKER
5925-00-420-8561INTERCHANGEABLE
CIRCUIT BREAKER
PDLA-40
5925-00-708-8769INTERCHANGEABLE
CIRCUIT BREAKER
5925-00-775-1717INTERCHANGEABLE
CIRCUIT BREAKER
5925-01-092-9694INTERCHANGEABLE
CIRCUIT BREAKER
5925-01-265-7692INTERCHANGEABLE
CIRCUIT BREAKER
5925-01-429-4554INTERCHANGEABLE
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-411-5170?

NSN 5925-00-411-5170 is a Circuit Breaker, manufactured by Military Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M, classified under FSC 5925 (No Item Name Available). Status: active.

What are the part numbers for NSN 5925-00-411-5170?

NSN 5925-00-411-5170 has 5 cross-referenced part numbers: MS39068-5 (Military Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M), M13516/7-10 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), 5925004115170 (E.c.a Etablissement Central Des Approvisionnements Des Forces Armees Royales), MIL-C-13516/7 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), M13516/7BII-120 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M).

What NSN replaces 5925-00-411-5170?

There are 9 known substitutes for 5925-00-411-5170: 5925-00-247-2076, 5925-00-295-5460, 5925-00-295-5462 and 6 more. Verify interchangeability with system specifications before substitution.

What are the specifications of MS39068-5?

Key specifications for MS39068-5: Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps: 575.0 DC SINGLE LOCATION; Maximum Continuous Load Current Rating Per Pole: 120.0 AMPERES DC SINGLE LOCATION; Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 138.0 SINGLE LOCATION; Body Style: SINGLE POLE TYPE. 27 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com