PartsTable
Technical Data Sheet

XVB730URED, LIGHT LIMIT — Cable Assembly Specs

✓ Verified by PartsTable
— · MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

The XVB730URED, LIGHT LIMIT is a the manufacturer industrial component. Key specifications include color: RED FIRST POSITION COVER SINGLE CONDUCTOR, material: PLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR, temp_rating: -55.0 CELSIUS AND 105.0 CELSIUS DEGC, conductor_form: STRANDED SINGLE CONDUCTOR, voltage_rating: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR, surface_treatment: TIN CORE CONDUCTOR SINGLE CONDUCTOR. This part is cataloged in the Federal Logistics Information System under NSN 6145-00-669-6705, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO→ MRO_GENERAL→ XVB730URED, LIGHT LIMIT
NSN: 6145-00-669-6705
FSC: 6145
CAGE: 90484 — RSCC WIRE & CABLE LLC (USA)
SPECIFICATIONS
colorRED FIRST POSITION COVER SINGLE CONDUCTOR
materialPLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
temp_rating-55.0 CELSIUS AND 105.0 CELSIUS DEGC
conductor_formSTRANDED SINGLE CONDUCTOR
voltage_rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
surface_treatmentTIN CORE CONDUCTOR SINGLE CONDUCTOR
round_conductor_size22 AWG SINGLE CONDUCTOR
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor30 SINGLE CONDUCTOR
strand_quantity_per_conductor7 SINGLE CONDUCTOR
cross_section_outside_diameter0.049 INCHES NOMINAL IN
material_document_and_classificationASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR
NSN6145-00-669-6705
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: XVB730URED, LIGHT LIMIT · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
•
CROSS SECTION OUTSIDE DIAMETER: 0.049 INCHES NOMINAL IN
•
SURFACE TREATMENT: TIN CORE CONDUCTOR SINGLE CONDUCTOR
•
CONDUCTOR FORM: STRANDED SINGLE CONDUCTOR
•
COLOR: RED FIRST POSITION COVER SINGLE CONDUCTOR
•
STRAND QUANTITY PER CONDUCTOR: 7 SINGLE CONDUCTOR
•
VOLTAGE RATING: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
•
ROUND CONDUCTOR SIZE: 22 AWG SINGLE CONDUCTOR
•
MATERIAL DOCUMENT AND CLASSIFICATION: ASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR
TECHNICAL CHARACTERISTICS
CROSS SECTION OUTSIDE DIAMETER0.049 INCHES NOMINAL IN
SURFACE TREATMENTTIN CORE CONDUCTOR SINGLE CONDUCTOR
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
COLORRED FIRST POSITION COVER SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR7 SINGLE CONDUCTOR
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
ROUND CONDUCTOR SIZE22 AWG SINGLE CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALPLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
VERIFIED SUBSTITUTES & CROSS-REFERENCES 28
M16878/1BKE9Upgraded SuccessorGOVERNMENT REGISTRY
successor cross-reference
successor
AS22759/16Upgraded SuccessorGOVERNMENT REGISTRY
successor cross-reference
successor
M22759/16-14-9Upgraded SuccessorGOVERNMENT REGISTRY
successor cross-reference
successor
1859/19-4Upgraded SuccessorGOVERNMENT REGISTRY
successor cross-reference
successor
M22759/16-14-5Upgraded SuccessorGOVERNMENT REGISTRY
successor cross-reference
successor
MIL-W-16878/1Upgraded SuccessorGOVERNMENT REGISTRY
successor cross-reference
successor
LIFECYCLE
StatusCANCELLEDGOVERNMENT REGISTRY
Availability—
RoHS CompliantEAR99Not HAZMATSourcing: other
Ready to buy XVB730URED, LIGHT LIMIT?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is XVB730URED, LIGHT LIMIT?
XVB730URED, LIGHT LIMIT is a XVB730URED, LIGHT LIMIT. It is classified as a MRO (MRO_GENERAL).
What parts can replace XVB730URED, LIGHT LIMIT?
There are 28 known substitutes for XVB730URED, LIGHT LIMIT: M16878/1BKE9, AS22759/16, M22759/16-14-9 and 25 more. Substitute compatibility should be verified for your specific system.
Is XVB730URED, LIGHT LIMIT still available?
XVB730URED, LIGHT LIMIT is currently cancelled.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — XVB730URED, LIGHT LIMIT