PartsTable
Technical Data Sheet

TPC115-10-A2/MTD — PANEL,POWER DISTRIBUTION

✓ Government record, cited
— · WIRE CABLE
PRODUCT OVERVIEW

TPC115-10-A2/MTD: PANEL,POWER DISTRIBUTION.

The PANEL,POWER DISTRIBUTION is a the manufacturer power supply unit built for continuous operation in enterprise server and storage platforms. Key specifications include outlet_type: SWITCHED, body_material: STEEL, overall_width: 8.000 INCHES NOMINAL IN, overall_height: 1.750 INCHES NOMINAL IN, overall_length: 19.000 INCHES NOMINAL IN, mounting_method: CHASSIS. This part is cataloged in the U.S.

Government catalog under NSN 6150-01-479-3371, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
TPC115-10-A2/MTD
NSN: 6150-01-479-3371
NIINs: 014793371, 014969035
FSC: 6150 — Miscellaneous Electric Power and Distribution Equipment
CAGE: 70513 — EATON CORPORATION DIV EATON POWERWARE EPDU (USA)
SPECIFICATIONS
outlet_typeSWITCHED
body_materialSTEEL
overall_width8.000 INCHES NOMINAL IN
overall_height1.750 INCHES NOMINAL IN
overall_length19.000 INCHES NOMINAL IN
mounting_methodCHASSIS
ac_voltage_rating120.0 VOLTS MAXIMUM
features_providedSPIKE PROTECTIVE
frequency_in_hertz60.0
mating_end_quantity8
current_rating_in_amps20.0
functional_descriptionPOWER PANEL
NSN6150-01-479-3371
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: TPC115-10-A2/MTD · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
•
FREQUENCY IN HERTZ: 60.0
•
AC VOLTAGE RATING: 120.0 VOLTS MAXIMUM
•
CURRENT INTERRUPTING CAPACITY: 20.0 AMPERES NOMINAL
•
MATING END QUANTITY: 8
•
MOUNTING METHOD: CHASSIS
TYPICAL APPLICATIONS
  • Server power supply replacement (failed or degraded)
  • Redundant power upgrade for high-availability
  • Power capacity upgrade for GPU or expansion configurations
  • Hot-swap power maintenance in production environments
  • Spare inventory for break-fix operations
TECHNICAL CHARACTERISTICS
OVERALL HEIGHT1.750 INCHES NOMINAL IN
FREQUENCY IN HERTZ60.0
AC VOLTAGE RATING120.0 VOLTS MAXIMUM
CURRENT INTERRUPTING CAPACITY20.0 AMPERES NOMINAL
MATING END QUANTITY8
MOUNTING METHODCHASSIS
OVERALL LENGTH19.000 INCHES NOMINAL IN
OVERALL WIDTH8.000 INCHES NOMINAL IN
OUTLET TYPESWITCHED
FEATURES PROVIDEDSPIKE PROTECTIVE
SUBSTITUTES & CROSS-REFERENCES

No substitute or cross-reference records for this part.

LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Insurance item — stocked against contingency demandNo demilitarization required
Ready to buy TPC115-10-A2/MTD?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is TPC115-10-A2/MTD?
TPC115-10-A2/MTD is a PANEL,POWER DISTRIBUTION.
What is the NSN for TPC115-10-A2/MTD?
TPC115-10-A2/MTD is cataloged in the U.S. Government catalog under NSN 6150-01-479-3371. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — TPC115-10-A2/MTD