The RELAY,ELECTROMAGNETIC is a the manufacturer industrial component. Key specifications include duty_type: CONTINUOUS, overall_length: 2.750 INCHES NOMINAL IN, overall_diameter: 2.000 INCHES NOMINAL IN, special_features: WEAPON SYSTEM ESSENTIAL, frequency_in_hertz: 60.0 NOMINAL, arc_quenching_method: INERT GAS. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5945-00-201-7822, indicating validated use in U.S.
government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.
| duty_type | CONTINUOUS |
| coil_quantity | 1 |
| overall_length | 2.750 INCHES NOMINAL IN |
| overall_diameter | 2.000 INCHES NOMINAL IN |
| special_features | WEAPON SYSTEM ESSENTIAL |
| winding_quantity | 1 |
| frequency_in_hertz | 60.0 NOMINAL |
| arc_quenching_method | INERT GAS |
| end_item_identification | TYPE NO. AN/CPN4; ADVANCED AIR TRAFFIC CONTROL, & LAND, SYS (ATCALS)404L; AIRCRAFT, PHANTOM F-4 |
| environmental_protection | HERMETIC |
| terminal_type_and_quantity | 10 PIN ALL FUNCTIONS |
| criticality_code_justification | FEAT |
| NSN | 5945-00-201-7822 |
| ARC QUENCHING METHOD | INERT GAS |
| DUTY TYPE | CONTINUOUS |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 20.0 MILLIAMPERES AC SINGLE WINDING |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 117.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| TERMINAL TYPE AND QUANTITY | 10 PIN ALL FUNCTIONS |