CABLE,SPECIAL PURPOSE,ELECTRICAL. Key specifications include material: COPPER FIRST POSITION CONDUCTOR SINGLE CONDUCTOR, temp_rating: 90.0 CELSIUS DEGC, voltage_rating: 600.0 SERVICE VOLTAGE SINGLE CONDUCTOR, outside_diameter: 0.805 INCHES NOMINAL SINGLE CONDUCTOR IN, strand_awg_size_per_conductor: 6 SINGLE CONDUCTOR, strand_quantity_per_conductor: 26 SINGLE CONDUCTOR. This part is cataloged in the U.S.
Government catalog under NSN 6145-01-652-6849, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
WHERE IT FITS
SOOW 6/2
NSN:6145-01-652-6849 FSC:6145 — Wire and Cable, Electrical CAGE:0X4C9 — ALLIED WIRE AND CABLE LLC DBA ALLIED WIRE AND CABLE INC DIV ALLIED WIRE & CABLE, LLC. (USA)
SPECIFICATIONS
material
COPPER FIRST POSITION CONDUCTOR SINGLE CONDUCTOR
temp_rating
90.0 CELSIUS DEGC
voltage_rating
600.0 SERVICE VOLTAGE SINGLE CONDUCTOR
outside_diameter
0.805 INCHES NOMINAL SINGLE CONDUCTOR IN
special_features
INSULATION MATERIAL - ETHYLENE PROPYLENE DIENE MONOMER RUBBER (EPDM); JACKET MATERIAL - THERMOPLASTIC ELASTOMER (TPE); NOMINAL INSULATION THICK 0.060 INCHES; JACKET THICK 0.090 INCHES; AMPS SS IN
conductor_quantity
2
strand_awg_size_per_conductor
6 SINGLE CONDUCTOR
strand_quantity_per_conductor
26 SINGLE CONDUCTOR
part_name_assigned_by_controlling_agency
S00W CABLE - 2 AWG TO 8 AWG
NSN
6145-01-652-6849
COMPONENT DIAGRAM
KEY FEATURES
•
TEMP RATING: 90.0 CELSIUS DEGC
•
VOLTAGE RATING: 600.0 SERVICE VOLTAGE SINGLE CONDUCTOR
•
CONDUCTOR QUANTITY: 2
•
STRAND AWG SIZE PER CONDUCTOR: 6 SINGLE CONDUCTOR
•
OUTSIDE DIAMETER: 0.805 INCHES NOMINAL SINGLE CONDUCTOR IN
•
STRAND QUANTITY PER CONDUCTOR: 26 SINGLE CONDUCTOR
TYPICAL APPLICATIONS
Server Internal Cabling
Data Center Cable Infrastructure
SAS/SATA Drive Connectivity
TECHNICAL CHARACTERISTICS
TEMP RATING
90.0 CELSIUS DEGC
VOLTAGE RATING
600.0 SERVICE VOLTAGE SINGLE CONDUCTOR
CONDUCTOR QUANTITY
2
STRAND AWG SIZE PER CONDUCTOR
6 SINGLE CONDUCTOR
OUTSIDE DIAMETER
0.805 INCHES NOMINAL SINGLE CONDUCTOR IN
STRAND QUANTITY PER CONDUCTOR
26 SINGLE CONDUCTOR
SPECIAL FEATURES
INSULATION MATERIAL - ETHYLENE PROPYLENE DIENE MONOMER RUBBER (EPDM); JACKET MATERIAL - THERMOPLASTIC ELASTOMER (TPE); NOMINAL INSULATION THICK 0.060 INCHES; JACKET THICK 0.090 INCHES; AMPS SS IN
PART NAME ASSIGNED BY CONTROLLING AGENCY
S00W CABLE - 2 AWG TO 8 AWG
MATERIAL
COPPER FIRST POSITION CONDUCTOR SINGLE CONDUCTOR
OTHER ITEMS IN FSC 6145 — Wire and Cable, Electrical
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is SOOW 6/2?
SOOW 6/2 is a CABLE,SPECIAL PURPOSE,ELECTRICAL.
What is the NSN for SOOW 6/2?
SOOW 6/2 is cataloged in the U.S. Government catalog under NSN 6145-01-652-6849. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.