WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

The CABLE ASSEMBLY,RADIO FREQUENCY is a the manufacturer cable assembly designed for reliable internal or external connectivity in enterprise server and storage environments. Key specifications include color: BLACK THIRD POSITION JACKET SINGLE CONDUCTOR, material: COPPER SECOND POSITION SHIELD BRAID METALLIC SINGLE CONDUCTOR, conductor_form: STRANDED SINGLE CONDUCTOR, overall_length: 48.000 INCHES IN, voltage_rating: 1400.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR, style_designator: INTERNAL AND EXTERNAL CONNECTOR. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-00-542-6092, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL RG58AU
NSN: 6145-00-542-6092
FSC: 6145
CAGE: 80058 — JOINT ELECTRONICS TYPE DESIGNATION SYSTEM (USA)
SPECIFICATIONS
colorBLACK THIRD POSITION JACKET SINGLE CONDUCTOR
materialCOPPER SECOND POSITION SHIELD BRAID METALLIC SINGLE CONDUCTOR
conductor_formSTRANDED SINGLE CONDUCTOR
overall_length48.000 INCHES IN
voltage_rating1400.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
style_designatorINTERNAL AND EXTERNAL CONNECTOR
termination_typeCONNECTOR PLUG BOTH ENDS SINGLE CONDUCTOR
surface_treatmentTIN SECOND POSITION SHIELD BRAID METALLIC SINGLE CONDUCTOR
conductor_quantity1
fsc_application_dataELECTRONIC STANDARDS,FIRE CONTROL MAINTENANCE
round_conductor_size20 AWG SINGLE CONDUCTOR
electrical_resistance50.00 OHMS IMPEDANCE
NSN6145-00-542-6092
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: RG58AU · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
MATERIAL: PLASTIC POLYVINYL CHLORIDE (PVC) THIRD POSITION JACKET SINGLE CONDUCTOR
CONDUCTOR QUANTITY: 1
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION: ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
CROSS-SECTIONAL SHAPE STYLE: ROUND
STRAND AWG SIZE PER CONDUCTOR: 33 SINGLE CONDUCTOR
VOLTAGE RATING: 1400.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
SURFACE TREATMENT: TIN SECOND POSITION SHIELD BRAID METALLIC SINGLE CONDUCTOR
TYPICAL APPLICATIONS
  • Server Internal Cabling
  • Data Center Cable Infrastructure
  • SAS/SATA Drive Connectivity
TECHNICAL CHARACTERISTICS (FLIS)
MATERIALPLASTIC POLYVINYL CHLORIDE (PVC) THIRD POSITION JACKET SINGLE CONDUCTOR
CONDUCTOR QUANTITY1
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
CROSS-SECTIONAL SHAPE STYLEROUND
STRAND AWG SIZE PER CONDUCTOR33 SINGLE CONDUCTOR
VOLTAGE RATING1400.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
SURFACE TREATMENTTIN SECOND POSITION SHIELD BRAID METALLIC SINGLE CONDUCTOR
MATERIALCOPPER SECOND POSITION SHIELD BRAID METALLIC SINGLE CONDUCTOR
COLORBLACK THIRD POSITION JACKET SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 SINGLE CONDUCTOR
VERIFIED SUBSTITUTES & CROSS-REFERENCES 30
MIL-DTL-17/75Upgraded Successor
successor cross-reference
successor
M17/164-00002Upgraded Successor
successor cross-reference
successor
M17/75-RG365Upgraded Successor
successor cross-reference
successor
PP15133-0Upgraded Successor
successor cross-reference
successor
B3009CG29-0Upgraded Successor
successor cross-reference
successor
M17/93-RG178-BLACKUpgraded Successor
successor cross-reference
successor
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy RG58AU?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is RG58AU?
RG58AU is a CABLE ASSEMBLY,RADIO FREQUENCY. It is classified as a MRO (MRO_GENERAL).
What parts can replace RG58AU?
There are 30 known substitutes for RG58AU: MIL-DTL-17/75, M17/164-00002, M17/75-RG365 and 27 more. Substitute compatibility should be verified for your specific system.
Is RG58AU still available?
RG58AU is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.