RF7175: FILTER,RADIO FREQUENCY INTERFERE.
FILTER,RADIO FREQUENCY INTERFERE. Key specifications include body_width: 1.900 INCHES MAXIMUM IN, body_length: 6.191 INCHES MAXIMUM IN, overall_height: 5.350 INCHES MAXIMUM IN, overall_length: 7.940 INCHES MAXIMUM IN, style_designator: RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES, maximum_voltage_drop_per_function: 1.2 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION. This part is cataloged in the U.S.
Government catalog under NSN 5915-01-260-4112, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| body_width | 1.900 INCHES MAXIMUM IN |
| body_length | 6.191 INCHES MAXIMUM IN |
| overall_height | 5.350 INCHES MAXIMUM IN |
| overall_length | 7.940 INCHES MAXIMUM IN |
| style_designator | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| maximum_voltage_drop_per_function | 1.2 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| unthreaded_mounting_hole_diameter | 0.276 INCHES MINIMUM AND 0.284 INCHES MAXIMUM IN |
| mounting_facility_type_and_quantity | 4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| operating_current_rating_per_function_in_amps | 20.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| operating_voltage_rating_and_type_per_function | 115.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| power_line_frequency_rating_per_function_in_hertz | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| distance_between_centerlines_of_mounting_facilities_parallel_to_body_width | 4.750 INCHES NOMINAL IN |
| NSN | 5915-01-260-4112 |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| OVERALL HEIGHT | 5.350 INCHES MAXIMUM IN |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 7.190 INCHES NOMINAL IN |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| BODY WIDTH | 1.900 INCHES MAXIMUM IN |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |