FILTER,RADIO FREQUENCY INTERFERE. Key specifications include inclosure_type: HERMETICALLY SEALED, operating_temp_range: -55.0 TO 85.0 CELSIUS DEGC, load_impedance_per_function: 5.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED, average_life_rating_in_hours: 10000.0, maximum_voltage_drop_per_function: 2.4 VOLTS AC BLANK AND 2.4 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED, source_impedance_rating_per_function: 5.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED. This product is currently in active production with full OEM support.
This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5915-00-197-0874, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| inclosure_type | HERMETICALLY SEALED |
| operating_temp_range | -55.0 TO 85.0 CELSIUS DEGC |
| load_impedance_per_function | 5.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| average_life_rating_in_hours | 10000.0 |
| maximum_voltage_drop_per_function | 2.4 VOLTS AC BLANK AND 2.4 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| source_impedance_rating_per_function | 5.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| functional_terminal_type_and_quantity | 2 WIRE LEAD OUTPUT SECOND FUNCTION |
| principal_circuitry_type_per_function | INDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| operating_current_rating_per_function_in_amps | 6.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| operating_voltage_rating_and_type_per_function | 130.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| power_line_frequency_rating_per_function_in_hertz | 440.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| NSN | 5915-00-197-0874 |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 6.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD OUTPUT SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| LOAD IMPEDANCE PER FUNCTION | 5.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| SOURCE IMPEDANCE RATING PER FUNCTION | 5.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 2.4 VOLTS AC BLANK AND 2.4 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD INPUT FIRST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED |