PER7: POWER STRIP,ELECTRICAL OUTLET.

Lightning and Surge Protection To prevent damage to your equipment from power surges and spikes. IEEE let-through ratings and regulatory agency compliance Stringent third-party testing gives you confidence that APC's surge protectors will safeguard your equipment and data from potentially damaging surges and spikes. Data-line Protection Protection of data lines (Ethernet, Coaxial and Phone lines) ensures complete protection of your equipment from surges.

It is very important to protect your equipment from “back door” surges traveling through data lines, as they can be as damaging to your equipment as surges traveling over power lines. Noise Filtering Surge Protector attenuates EMI/RFI line noise that can cause data errors and keyboard lockups, ensuring better performance of protected equipment. Catastrophic Event Protection SurgeArrest components such as MOVs and Thermal fuse ensure instantaneous reaction to lightning s This part is cataloged in the U.S.

Government catalog under NSN 6150-01-419-8708, indicating validated use in U.S. government and defense logistics supply chains.

WHERE IT FITS
PER7
NSN: 6150-01-419-8708
FSC: 6150 — Miscellaneous Electric Power and Distribution Equipment
CAGE: 0MG77 — SCHNEIDER ELECTRIC IT CORPORATION DBA A P S SALES & SERVICE DIV SCHNEIDER ELECTRIC IT CORP. (USA)
SPECIFICATIONS
body_materialPLASTIC
overall_width4.250 INCHES NOMINAL IN
overall_height2.000 INCHES NOMINAL IN
overall_length10.500 INCHES NOMINAL IN
frequency_in_hertz60.0
mating_end_quantity7
current_rating_in_amps15.0
current_interrupting_capacity6.5 AMPERES NOMINAL
NSN6150-01-419-8708
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: PER7 · APC ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
•
FREQUENCY IN HERTZ: 60.0
•
CURRENT INTERRUPTING CAPACITY: 6.5 AMPERES NOMINAL
•
MATING END QUANTITY: 7
•
BODY MATERIAL: PLASTIC
•
CURRENT RATING IN AMPS: 15.0
TECHNICAL CHARACTERISTICS
OVERALL HEIGHT2.000 INCHES NOMINAL IN
FREQUENCY IN HERTZ60.0
CURRENT INTERRUPTING CAPACITY6.5 AMPERES NOMINAL
MATING END QUANTITY7
OVERALL LENGTH10.500 INCHES NOMINAL IN
OVERALL WIDTH4.250 INCHES NOMINAL IN
BODY MATERIALPLASTIC
CURRENT RATING IN AMPS15.0
OTHER ITEMS IN FSC 6150 — Miscellaneous Electric Power and Distribution Equipment
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6150-00-000-0125 6150-00-000-0174 6150-00-000-0176 6150-00-000-0178 6150-00-000-0179 6150-00-000-0180 6150-00-001-1272 6150-00-001-1522
SUBSTITUTES & CROSS-REFERENCES

No substitute or cross-reference records for this part.

LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Normally procured from the manufacturer (OEM)No demilitarization required
Ready to buy PER7?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is PER7?
PER7 is a POWER STRIP,ELECTRICAL OUTLET manufactured by APC.
What is the NSN for PER7?
PER7 is cataloged in the U.S. Government catalog under NSN 6150-01-419-8708. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — PER7