PAL2000: RECORDER,HUMIDITY-TEMPERATURE.
The RECORDER,HUMIDITY-TEMPERATURE is a DALLAS INSTRUMENTS INC cable assembly designed for reliable internal or external connectivity in enterprise server and storage environments. Key specifications include CURRENT TYPE: DC, CUBIC MEASURE: 737.000 CUBIC CENTIMETERS, OVERALL DEPTH: 3.800 INCHES NOMINAL IN, OVERALL HEIGHT: 2.400 INCHES NOMINAL IN, OVERALL LENGTH: 4.900 INCHES NOMINAL IN, OPERATING RANGE: -30.0 TO 70.0 DEG CELSIUS. This part is cataloged in the U.S.
Government catalog under NSN 6685-01-463-0554, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| CURRENT TYPE | DC |
| CUBIC MEASURE | 737.000 CUBIC CENTIMETERS |
| OVERALL DEPTH | 3.800 INCHES NOMINAL IN |
| OVERALL HEIGHT | 2.400 INCHES NOMINAL IN |
| OVERALL LENGTH | 4.900 INCHES NOMINAL IN |
| OPERATING RANGE | -30.0 TO 70.0 DEG CELSIUS |
| DC VOLTAGE RATING | 6.0 VOLTS NOMINAL |
| INFORMATION RECORDED | AIR TEMPERATURE AND RELATIVE HUMIDITY AND TIME AND SIGNAL DATA |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | PEAK ACCELLERATION LOGGER |
| NSN | 6685-01-463-0554 |
| OVERALL HEIGHT | 2.400 INCHES NOMINAL IN |
| CURRENT TYPE | DC |
| DC VOLTAGE RATING | 6.0 VOLTS NOMINAL |
| SUPPLEMENTARY FEATURES | TRIAXIAL ACCELEROMETER, USER SELECTABLE RANGES (5, 10, 20, 50, 100, 200G FULL SCALE), RNGES SELECTABLE FOR EACH AXIS. BUILT IN TEMP AND RH TRANSDUCERS; TEMP MEASUREMENT RANGE: -30 TO 70 DEG C (LITHIUM) & -20 TO 54 DEG C (ALKALINE), +/1,5 DEG C; RELATIVE HUMIDITY: 0 TO 100% @ 25 DEG C, +/-4% FROM 5 TO 95%RH NONCONDENSING @ 25 DEG C G |
| OVERALL LENGTH | 4.900 INCHES NOMINAL IN |
| INFORMATION RECORDED | AIR TEMPERATURE AND RELATIVE HUMIDITY AND TIME AND SIGNAL DATA |
| SPECIAL FEATURES | RECORDS THE FOLLOWING:PEAK ACCELERATION & DURATION, VELOCITY CHANGE, NUMBER OF ACCER LERATION PULSES, TEMPERATURE & RELATIVE HUMIDITY, DATE & TIME STAMP; CASE MATL ALUMINUM 6061-T6; USES4 ALKALINE OR LITHIUM C SIZE BATTERIES; OPERATES UP TO 60 DAYS (ALKALINE), & 120 DAY (LITHIUM); LCD OPERATING TEMP: -20 TO 50 DEG C; MEMORY; 1 MN STATIC RAM, MEMORY MODE; FILL/STOP & WRAP, READING DATA FOR 1 YEAR AFTER BATTERIES ARE EXHAUSTED OR REMOVED; RS232 SERIAL INTERFACE OUTPUT DEGC |
| CUBIC MEASURE | 737.000 CUBIC CENTIMETERS |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | PEAK ACCELLERATION LOGGER |
| OPERATING RANGE | -30.0 TO 70.0 DEG CELSIUS |
No substitute or cross-reference records for this part.