P23648-018-01: RESISTOR,THERMAL.
The RESISTOR,THERMAL is a the manufacturer industrial component. Key specifications include inclosure_type: ENCAPSULATED, terminal_length: 3.000 INCHES NOMINAL3.000 INCHES NOMINAL IN, style_designator: BEAD, surface_treatment: SOLDER TERMINAL, terminal_diameter: 0.00795 INCHES NOMINAL0.00795 INCHES NOMINAL IN, body_outside_diameter: 0.095 INCHES MAXIMUM0.095 INCHES MAXIMUM IN. This part is cataloged in the U.S.
Government catalog under NSN 5905-01-137-4860, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| inclosure_type | ENCAPSULATED |
| terminal_length | 3.000 INCHES NOMINAL3.000 INCHES NOMINAL IN |
| style_designator | BEAD |
| surface_treatment | SOLDER TERMINAL |
| terminal_diameter | 0.00795 INCHES NOMINAL0.00795 INCHES NOMINAL IN |
| body_outside_diameter | 0.095 INCHES MAXIMUM0.095 INCHES MAXIMUM IN |
| reliability_indicator | NOT ESTABLISHEDNOT ESTABLISHED |
| zero_power_resistance | 30.000 KILOHMS |
| maximum_operating_temp | 150.0 CELSIUS150.0 CELSIUS DEGC |
| terminal_type_and_quantity | 2 WIRE LEAD |
| reference_temp_in_deg_celsius | 25.0 |
| ambient_temp_at_full_rated_power | 25.0 CELSIUS25.0 CELSIUS DEGC |
| NSN | 5905-01-137-4860 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -20.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT-20.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT DEGC |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT DEGC |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT150.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT DEGC |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT-40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT DEGC |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT100.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT DEGC |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 120.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT120.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT DEGC |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 135.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT135.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT DEGC |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 20.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT20.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT DEGC |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT50.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT DEGC |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 70.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT70.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT DEGC |