PartsTable
Technical Data Sheet
Download PDF

NQP-1924SJ — NQP-1924SJ

✓ Government record, cited
— · MRO · MRO_GENERAL
PRODUCT OVERVIEW

NQP-1924SJ: NQP-1924SJ.

The NQP-1924SJ is a the manufacturer industrial component. Key specifications include color: GRAY/GREY FIRST POSITION JACKET CABLE, material: PLASTIC POLYVINYL CHLORIDE (PVC) THIRD POSITION JACKET CABLE, temp_rating: -40.0 CELSIUS AND 105.0 CELSIUS DEGC, conductor_form: STRANDED ALL CONDUCTORS, voltage_rating: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS, special_features: OUTER JACKET CONFORMS TO MIL-I-631 CLASS F. This part is cataloged in the U.S.

Government catalog under NSN 6145-01-219-3070, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO→ MRO_GENERAL→ NQP-1924SJ
NSN: 6145-01-219-3070
FSC: 6145 — Wire and Cable, Electrical
CAGE: 04569 — NATIONAL WIRE AND CABLE CORPORATION DBA NATIONAL WIRE AND CABLE DIV NATIONAL CABLE MOLDING CORPORATION (USA)
SPECIFICATIONS
colorGRAY/GREY FIRST POSITION JACKET CABLE
materialPLASTIC POLYVINYL CHLORIDE (PVC) THIRD POSITION JACKET CABLE
temp_rating-40.0 CELSIUS AND 105.0 CELSIUS DEGC
conductor_formSTRANDED ALL CONDUCTORS
voltage_rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
special_featuresOUTER JACKET CONFORMS TO MIL-I-631 CLASS F
surface_treatmentTIN CORE CONDUCTOR ALL CONDUCTORS
conductor_quantity38
round_conductor_size24 AWG ALL CONDUCTORS
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor32 ALL CONDUCTORS
strand_quantity_per_conductor7 ALL CONDUCTORS
NSN6145-01-219-3070
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: NQP-1924SJ · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
•
ROUND CONDUCTOR SIZE: 24 AWG ALL CONDUCTORS
•
COLOR CODING DOCUMENT: NQP-04569 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
•
TEMP RATING: -40.0 CELSIUS AND 105.0 CELSIUS DEGC
•
VOLTAGE RATING: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
•
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION: ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
•
CONDUCTOR QUANTITY: 38
•
STRAND AWG SIZE PER CONDUCTOR: 32 ALL CONDUCTORS
•
MATERIAL DOCUMENT AND CLASSIFICATION: ASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS
TECHNICAL CHARACTERISTICS
ROUND CONDUCTOR SIZE24 AWG ALL CONDUCTORS
COLOR CODING DOCUMENTNQP-04569 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TEMP RATING-40.0 CELSIUS AND 105.0 CELSIUS DEGC
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
CONDUCTOR QUANTITY38
STRAND AWG SIZE PER CONDUCTOR32 ALL CONDUCTORS
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEROUND
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
SUBSTITUTES & CROSS-REFERENCES 1
12688Same NSN cross-reference
Same NSN cross-reference
Also cataloged under this NSN
LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Normally procured from the manufacturer (OEM)No demilitarization required
Ready to buy NQP-1924SJ?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is NQP-1924SJ?
NQP-1924SJ is a NQP-1924SJ. It is classified as a MRO (MRO_GENERAL).
What parts can replace NQP-1924SJ?
There is 1 known substitute for NQP-1924SJ: 12688. Substitute compatibility should be verified for your specific system.
What is the NSN for NQP-1924SJ?
NQP-1924SJ is cataloged in the U.S. Government catalog under NSN 6145-01-219-3070. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — NQP-1924SJ