MS90328-25A ✓ Verified by PartsTable
· WIRE CABLE
WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

CABLE ASSEMBLY,POWER,ELECTRICAL. Key specifications include material: RUBBER NATURAL FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS, conductor_form: STRANDED ALL CONDUCTORS, overall_length: 20.000 FEET FT, style_designator: EXTERNAL CONNECTOR AND LUG, termination_type: CONNECTOR EXTERNAL STRAIGHT FIRST END ALL CONDUCTORS, round_conductor_size: 0 AWG FIRST CONDUCTOR. This product is currently in active production with full OEM support.

This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6150-00-032-4821, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MS90328-25A
NSN: 6150-00-032-4821
FSC: 6150
CAGE: 96906 — MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
SPECIFICATIONS
materialRUBBER NATURAL FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
conductor_formSTRANDED ALL CONDUCTORS
overall_length20.000 FEET FT
style_designatorEXTERNAL CONNECTOR AND LUG
termination_typeCONNECTOR EXTERNAL STRAIGHT FIRST END ALL CONDUCTORS
conductor_quantity6
round_conductor_size0 AWG FIRST CONDUCTOR
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor34 ALL CONDUCTORS
material_document_and_classificationMIL-I-3930,TYPE IS MIL SPEC SINGLE MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
terminal_commercial_and_government_entity_code96906 SECOND END ALL CONDUCTORS
NSN6150-00-032-4821
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: MS90328-25A · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
CROSS-SECTIONAL SHAPE STYLE: ROUND
ROUND CONDUCTOR SIZE: 0 AWG SECOND CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATION: MIL-I-3930,TYPE IS MIL SPEC SINGLE MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
CONDUCTOR QUANTITY: 6
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE: 96906 SECOND END ALL CONDUCTORS
TERMINATION TYPE: CONNECTOR EXTERNAL STRAIGHT FIRST END ALL CONDUCTORS
TYPICAL APPLICATIONS
  • Server Internal Cabling
  • Data Center Cable Infrastructure
  • SAS/SATA Drive Connectivity
TECHNICAL CHARACTERISTICS (FLIS)
CROSS-SECTIONAL SHAPE STYLEROUND
OVERALL LENGTH20.000 FEET FT
ROUND CONDUCTOR SIZE0 AWG SECOND CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATIONMIL-I-3930,TYPE IS MIL SPEC SINGLE MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
ROUND CONDUCTOR SIZE12 AWG FIFTH CONDUCTOR
CONDUCTOR QUANTITY6
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE96906 SECOND END ALL CONDUCTORS
TERMINATION TYPECONNECTOR EXTERNAL STRAIGHT FIRST END ALL CONDUCTORS
ROUND CONDUCTOR SIZE12 AWG SIXTH CONDUCTOR
ROUND CONDUCTOR SIZE0 AWG FIRST CONDUCTOR
VERIFIED SUBSTITUTES & CROSS-REFERENCES 2
MIL-C-7974Interchangeable
Same NIIN cross-reference
interchangeable
MS25486-18Interchangeable
Same NIIN cross-reference
interchangeable
LIFECYCLE
StatusACTIVE
AvailabilityOEM and secondary market
RoHS CompliantEAR99Not HAZMAT
Ready to buy MS90328-25A?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is MS90328-25A?
MS90328-25A is a CABLE ASSEMBLY,POWER,ELECTRICAL.
What parts can replace MS90328-25A?
There are 2 known substitutes for MS90328-25A: MIL-C-7974, MS25486-18. Substitute compatibility should be verified for your specific system.
What is the NSN for MS90328-25A?
MS90328-25A is cataloged in the Federal Logistics Information System (FLIS) under NSN 6150-00-032-4821. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — MS90328-25A