ML87199: FILTER,LOW PASS.
The FILTER,LOW PASS is a the manufacturer industrial component. Key specifications include body_width: 2.937 INCHES MINIMUM AND 3.062 INCHES MAXIMUM IN, body_height: 4.750 INCHES MINIMUM AND 4.875 INCHES MAXIMUM IN, body_length: 3.437 INCHES MINIMUM AND 3.562 INCHES MAXIMUM IN, inclosure_type: HERMETICALLY SEALED, overall_height: 5.063 INCHES MINIMUM AND 5.250 INCHES MAXIMUM IN, style_designator: RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE. This part is cataloged in the U.S.
Government catalog under NSN 5915-00-995-3820, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| body_width | 2.937 INCHES MINIMUM AND 3.062 INCHES MAXIMUM IN |
| body_height | 4.750 INCHES MINIMUM AND 4.875 INCHES MAXIMUM IN |
| body_length | 3.437 INCHES MINIMUM AND 3.562 INCHES MAXIMUM IN |
| inclosure_type | HERMETICALLY SEALED |
| overall_height | 5.063 INCHES MINIMUM AND 5.250 INCHES MAXIMUM IN |
| style_designator | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| operating_temp_range | -0.0 TO 65.0 CELSIUS DEGC |
| load_impedance_per_function | 10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| reference_frequency_per_function | 9.33 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| frequency_band_width_per_function | 7.60 HERTZ BLANK AND 11.00 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| input_impedance_per_function_w/load | 10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| mounting_facility_type_and_quantity | 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| NSN | 5915-00-995-3820 |
| REFERENCE FREQUENCY PER FUNCTION | 9.33 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| OVERALL HEIGHT | 5.063 INCHES MINIMUM AND 5.250 INCHES MAXIMUM IN |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | 18.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.609 INCHES MINIMUM AND 2.625 INCHES MAXIMUM IN |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET OUTPUT SECOND FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET GROUND THIRD FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET INPUT FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |