PartsTable
Technical Data Sheet
MILC27500-20C2T2 ✓ Verified by PartsTable
· MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

The MILC27500-20C2T2 is a the manufacturer industrial component. Key specifications include color: BLUE FIRST POSITION COVER FIRST CONDUCTOR, material: COPPER FIRST POSITION SHIELD BRAID METALLIC CABLE, temp_rating: 105.0 CELSIUS DEGC, conductor_form: STRANDED ALL CONDUCTORS, voltage_rating: 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS, surface_treatment: TIN CORE CONDUCTOR ALL CONDUCTORS. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-00-058-6739, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL MILC27500-20C2T2
NSN: 6145-00-058-6739
FSC: 6145
CAGE: 83642 — STANDARDIZATION DIVISION DIRECTORATE OF LOGISTICS SERVICES (USA)
SPECIFICATIONS
colorBLUE FIRST POSITION COVER FIRST CONDUCTOR
materialCOPPER FIRST POSITION SHIELD BRAID METALLIC CABLE
temp_rating105.0 CELSIUS DEGC
conductor_formSTRANDED ALL CONDUCTORS
voltage_rating600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
surface_treatmentTIN CORE CONDUCTOR ALL CONDUCTORS
conductor_quantity2
round_conductor_size20 AWG ALL CONDUCTORS
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor32 ALL CONDUCTORS
strand_quantity_per_conductor19 ALL CONDUCTORS
cross_section_outside_diameter0.240 INCHES NOMINAL IN
NSN6145-00-058-6739
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: MILC27500-20C2T2 · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
CONDUCTOR ARRANGEMENT AND QUANTITY: 2 SINGLES
MATERIAL: TIN SECOND POSITION SHIELD BRAID METALLIC CABLE
STRAND AWG SIZE PER CONDUCTOR: 32 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR: 19 ALL CONDUCTORS
MATERIAL DOCUMENT AND CLASSIFICATION: QQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLE: ROUND
CROSS SECTION OUTSIDE DIAMETER: 0.240 INCHES NOMINAL IN
TECHNICAL CHARACTERISTICS (FLIS)
CONDUCTOR ARRANGEMENT AND QUANTITY2 SINGLES
MATERIALTIN SECOND POSITION SHIELD BRAID METALLIC CABLE
STRAND AWG SIZE PER CONDUCTOR32 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIAL DOCUMENT AND CLASSIFICATIONQQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEROUND
CROSS SECTION OUTSIDE DIAMETER0.240 INCHES NOMINAL IN
ROUND CONDUCTOR SIZE20 AWG ALL CONDUCTORS
CONDUCTOR QUANTITY2
VERIFIED SUBSTITUTES & CROSS-REFERENCES 15
M27500-22SC7G23Upgraded Successor
successor cross-reference
successor
M275600-22SC7G23Upgraded Successor
successor cross-reference
successor
MIL-C-27500Upgraded Successor
successor cross-reference
successor
5M1005-22R6S6Upgraded Successor
successor cross-reference
successor
M27500A22RC6S06Upgraded Successor
successor cross-reference
successor
M27500-14B1T02Upgraded Successor
successor cross-reference
successor
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy MILC27500-20C2T2?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is MILC27500-20C2T2?
MILC27500-20C2T2 is a MILC27500-20C2T2. It is classified as a MRO (MRO_GENERAL).
What parts can replace MILC27500-20C2T2?
There are 15 known substitutes for MILC27500-20C2T2: M27500-22SC7G23, M275600-22SC7G23, MIL-C-27500 and 12 more. Substitute compatibility should be verified for your specific system.
Is MILC27500-20C2T2 still available?
MILC27500-20C2T2 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — MILC27500-20C2T2