MIL-R-39016/26: RELAY,ELECTROMAGNETIC.
The RELAY,ELECTROMAGNETIC is a the manufacturer industrial component. Key specifications include duty_type: CONTINUOUS, time_delay: 0.004 SECONDS MAXIMUM FIXED OPERATE TIME, storage_type: GENERAL PURPOSE WAREHOUSE, cubic_measure: 0.040 CUBIC INCHES, overall_height: 0.375 INCHES MAXIMUM IN, overall_length: 0.375 INCHES MAXIMUM IN. This part is cataloged in the U.S.
Government catalog under NSN 5945-01-097-4192, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| duty_type | CONTINUOUS |
| time_delay | 0.004 SECONDS MAXIMUM FIXED OPERATE TIME |
| storage_type | GENERAL PURPOSE WAREHOUSE |
| coil_quantity | 1 |
| cubic_measure | 0.040 CUBIC INCHES |
| overall_height | 0.375 INCHES MAXIMUM IN |
| overall_length | 0.375 INCHES MAXIMUM IN |
| fragility_factor | MODERATELY RUGGED |
| overall_diameter | 0.335 INCHES MAXIMUM IN |
| special_features | FAILURE RATE LEVEL OF 1.000 PERCENT PER TEN THOUSAND CYCLES |
| winding_quantity | 1 |
| features_provided | LATCHING CONTACTS |
| NSN | 5945-01-097-4192 |
| MOUNTING FACILITY TYPE AND QUANTITY | 5 TERMINAL SINGLE MOUNTING FACILITY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| OVERALL DIAMETER | 0.370 INCHES MAXIMUM IN |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.1 AMPERES DC LAMP LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.2 AMPERES DC INDUCTIVE LOAD |
| OVERALL LENGTH | 1.875 INCHES MAXIMUM IN |
| WINDING DC RESISTANCE RATING | 1025.0 OHMS NOMINAL SINGLE WINDING |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 11.1 MILLIAMPERES DC SINGLE WINDING |
| TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE TIME |