MIL-PRF-39019/3: INTERRUPTER,GROUND FAULT.

The INTERRUPTER,GROUND FAULT is a the manufacturer industrial component. Key specifications include material: ALUMINUM OR PLASTIC CASE, body_style: MULTIPOLE-SINGLE ACTUATOR TYPE, body_width: 1.281 INCHES MAXIMUM IN, body_length: 1.562 INCHES MAXIMUM IN, reset_method: MANUAL, storage_type: GENERAL PURPOSE WAREHOUSE. This part is cataloged in the U.S.

Government catalog under NSN 5925-00-603-7002, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO→ MRO_GENERAL→ MIL-PRF-39019/3
NSN: 5925-00-603-7002
NIINs: 006037002, 010186843, 010201748, 010281717, 010286504, 010349175, 010349177, 010375866, 010376878, 010376881, 010378753, 010393073, 010393763, 010412585, 010421234, 010422543, 010457173, 010460375, 010471469, 010474688, 010477509, 010487087, 010525128, 010605265, 010666225, 010682435, 010730849, 010738951, 010753809, 010856441, 010917215, 010918964, 010922482, 010926291, 010926292, 011170702, 011208756, 011235152, 011235153, 011315869, 011348031, 011553721, 011568708, 011670077, 011670078, 011766569, 011809353, 011876118, 011882508, 011935471, 011947533, 012004929, 012078372, 012117745, 012125706, 012166102, 012429945, 012495861, 012607224, 012607225, 012657705, 012657706, 012657707, 012668972, 012715373, 012746984, 012845270, 012861548, 012929101, 012962882, 012965359, 013123378, 013194500, 013480346, 013594080, 013676118, 013705793, 013907154, 013914986, 013921112, 013972655, 014113466, 014156551, 014190212, 014193030, 014196209, 014206211, 014313692, 014375719, 014379172, 014380625, 014427232, 014427357, 014486841, 014486866, 014493714, 014600451, 014648026, 014852000, 014859638, 015128731, 015213915, 015239056, 015276844, 015449093, 015449096, 015518076, 015532874, 015688914, 015956167, 015960292, 015966171, 016182361, 016278177, 016412802, 016436931, 016708174, 016789263, 016801736, 016890083, 016996287, 017292398
FSC: 5925 — Circuit Breakers
CAGE: 81349 — MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
SPECIFICATIONS
materialALUMINUM OR PLASTIC CASE
body_styleMULTIPOLE-SINGLE ACTUATOR TYPE
body_width1.281 INCHES MAXIMUM IN
body_length1.562 INCHES MAXIMUM IN
reset_methodMANUAL
storage_typeGENERAL PURPOSE WAREHOUSE
overall_width1.281 INCHES MAXIMUM IN
pole_quantity2
bushing_length0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN
overall_height2.955 INCHES MAXIMUM IN
overall_length1.562 INCHES MAXIMUM IN
fragility_factorMODERATELY RUGGED
NSN5925-00-603-7002
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available INTERRUPTER,GROUND FAULT TITLE COMPONENT PN MIL-PRF-39019/3 MFR INTERRUPTER,GROUND FAU
KEY FEATURES
•
BUSHING LENGTH: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN
•
RESET METHOD: MANUAL
•
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
•
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC AND 50.0 DC ALL LOCATIONS
•
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING WITH PANEL SEAL
•
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
•
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
•
UNPACKAGED UNIT WEIGHT: 100.0 GRAMS NOMINAL G
TECHNICAL CHARACTERISTICS
BUSHING LENGTH0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN
RESET METHODMANUAL
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC AND 50.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING WITH PANEL SEAL
ACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
FREQUENCY IN HERTZ400.0 ALL LOCATIONS
UNPACKAGED UNIT WEIGHT100.0 GRAMS NOMINAL G
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN
BODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
OTHER ITEMS IN FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277 5925-00-001-2809 5925-00-001-3838 5925-00-001-5748 5925-00-001-5926 5925-00-001-5938 5925-00-001-5942 5925-00-001-5977
SUBSTITUTES & CROSS-REFERENCES 4
7907116-29Reference document
Same NSN cross-reference
Reference document — Advisory reference — outside the item-of-supply concept
M39019-3-118Reference document
Same NSN cross-reference
Reference document — Secondary reference
MIL-C-39019/3Reference document
Same NSN cross-reference
Reference document — Secondary reference
M39019/03-252Same NSN cross-reference
Same NSN cross-reference
Also cataloged under this NSN
LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Normally procured from the manufacturer (OEM)No demilitarization required
Ready to buy MIL-PRF-39019/3?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is MIL-PRF-39019/3?
MIL-PRF-39019/3 is a INTERRUPTER,GROUND FAULT. It is classified as a MRO (MRO_GENERAL).
What parts can replace MIL-PRF-39019/3?
There are 4 known substitutes for MIL-PRF-39019/3: 7907116-29, M39019-3-118, MIL-C-39019/3 and 1 more. Substitute compatibility should be verified for your specific system.
What is the NSN for MIL-PRF-39019/3?
MIL-PRF-39019/3 is cataloged in the U.S. Government catalog under NSN 5925-00-603-7002. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — MIL-PRF-39019/3