Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

The M76MWPC1419A9 is a the manufacturer industrial component. Key specifications include color: WHITE FIRST POSITION COVER SINGLE CONDUCTOR, material: COPPER CORE CONDUCTOR SINGLE CONDUCTOR, temp_rating: 80.0 CELSIUS DEGC, conductor_form: STRANDED SINGLE CONDUCTOR, voltage_rating: 1000.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR, surface_treatment: TIN CORE CONDUCTOR SINGLE CONDUCTOR. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-00-164-7027, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL M76MWPC1419A9
NSN: 6145-00-164-7027
FSC: 6145
CAGE: 81349 — MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
SPECIFICATIONS
colorWHITE FIRST POSITION COVER SINGLE CONDUCTOR
materialCOPPER CORE CONDUCTOR SINGLE CONDUCTOR
temp_rating80.0 CELSIUS DEGC
conductor_formSTRANDED SINGLE CONDUCTOR
voltage_rating1000.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
surface_treatmentTIN CORE CONDUCTOR SINGLE CONDUCTOR
round_conductor_size14 AWG SINGLE CONDUCTOR
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor27 SINGLE CONDUCTOR
strand_quantity_per_conductor19 SINGLE CONDUCTOR
cross_section_outside_diameter0.112 INCHES NOMINAL IN
material_document_and_classificationMIL-I-3930,TYPE 1P MIL SPEC SINGLE MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
NSN6145-00-164-7027
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: M76MWPC1419A9 · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
STRAND QUANTITY PER CONDUCTOR: 19 SINGLE CONDUCTOR
ROUND CONDUCTOR SIZE: 14 AWG SINGLE CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATION: MIL-I-3930,TYPE 1P MIL SPEC SINGLE MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
SURFACE TREATMENT: TIN CORE CONDUCTOR SINGLE CONDUCTOR
VOLTAGE RATING: 1000.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR: 27 SINGLE CONDUCTOR
MATERIAL: COPPER CORE CONDUCTOR SINGLE CONDUCTOR
TEMP RATING: 80.0 CELSIUS DEGC
TECHNICAL CHARACTERISTICS (FLIS)
STRAND QUANTITY PER CONDUCTOR19 SINGLE CONDUCTOR
ROUND CONDUCTOR SIZE14 AWG SINGLE CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATIONMIL-I-3930,TYPE 1P MIL SPEC SINGLE MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
SURFACE TREATMENTTIN CORE CONDUCTOR SINGLE CONDUCTOR
VOLTAGE RATING1000.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR27 SINGLE CONDUCTOR
MATERIALCOPPER CORE CONDUCTOR SINGLE CONDUCTOR
TEMP RATING80.0 CELSIUS DEGC
CROSS-SECTIONAL SHAPE STYLEROUND
COLORWHITE FIRST POSITION COVER SINGLE CONDUCTOR
VERIFIED SUBSTITUTES & CROSS-REFERENCES 24
19D321320-6Upgraded Successor
successor cross-reference
successor
M16878/18BGB6Upgraded Successor
successor cross-reference
successor
MW-C20(7)J6Upgraded Successor
successor cross-reference
successor
MIL-DTL-76Upgraded Successor
successor cross-reference
successor
MIL-W-76Upgraded Successor
successor cross-reference
successor
M76MWPC1816B7Upgraded Successor
successor cross-reference
successor
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy M76MWPC1419A9?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is M76MWPC1419A9?
M76MWPC1419A9 is a M76MWPC1419A9. It is classified as a MRO (MRO_GENERAL).
What parts can replace M76MWPC1419A9?
There are 24 known substitutes for M76MWPC1419A9: 19D321320-6, M16878/18BGB6, MW-C20(7)J6 and 21 more. Substitute compatibility should be verified for your specific system.
Is M76MWPC1419A9 still available?
M76MWPC1419A9 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — M76MWPC1419A9