CAPACITOR,FIXED,PLASTIC DIELECTR. Key specifications include body_style: W/O MTG FACILITIES, AXIAL TERMINALS, body_length: 0.687 INCHES NOMINAL IN, body_diameter: 0.235 INCHES MINIMUM AND 0.255 INCHES MAXIMUM IN, terminal_length: 1.625 INCHES MINIMUM IN, features_provided: HERMETICALLY SEALED CASE, reliability_indicator: ESTABLISHED. This product is currently in active production with full OEM support.
This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5910-00-174-6994, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| body_style | W/O MTG FACILITIES, AXIAL TERMINALS |
| body_length | 0.687 INCHES NOMINAL IN |
| body_diameter | 0.235 INCHES MINIMUM AND 0.255 INCHES MAXIMUM IN |
| terminal_length | 1.625 INCHES MINIMUM IN |
| features_provided | HERMETICALLY SEALED CASE |
| reliability_indicator | ESTABLISHED |
| case_insulation_material | PLASTIC |
| nonderated_operating_temp | -55.0 CELSIUS MINIMUM AND 100.0 CELSIUS MAXIMUM DEGC |
| terminal_surface_treatment | SOLDER |
| terminal_type_and_quantity | 2 UNINSULATED WIRE LEAD |
| tolerance_range_per_section | -1.00 TO 1.00 PERCENT SINGLE SECTION |
| schematic_diagram_designator | NO COMMON OR GROUNDED ELECTRODE(S) |
| NSN | 5910-00-174-6994 |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| RELIABILITY INDICATOR | ESTABLISHED |
| CAPACITANCE VALUE PER SECTION | 0.150 MICROFARADS SINGLE SECTION |
| TERMINAL LENGTH | 1.625 INCHES MINIMUM IN |
| CASE INSULATION MATERIAL | PLASTIC |
| TEST DATA DOCUMENT | 81349-MIL-C-39022/9 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TERMINAL SURFACE TREATMENT | SOLDER |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.2500 |
| MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-2 |