The POWER SUPPLY is a the manufacturer power supply unit built for continuous operation in enterprise server and storage platforms. Key specifications include input_phase: SINGLE SINGLE OPERATING POWER RQMT, overall_width: 8.500 INCHES NOMINAL IN, overall_height: 3.468 INCHES NOMINAL IN, overall_length: 13.687 INCHES NOMINAL IN, special_features: SINGLE OUTPUT DUAL RANGE; CROWBAROVERVOLTAGE PROTECTION, input_voltage_rating: 105.0 AC VOLTS MINIMUM AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT. This product is currently in active production with full OEM support.
This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6130-00-463-4638, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| input_phase | SINGLE SINGLE OPERATING POWER RQMT |
| overall_width | 8.500 INCHES NOMINAL IN |
| overall_height | 3.468 INCHES NOMINAL IN |
| overall_length | 13.687 INCHES NOMINAL IN |
| special_features | SINGLE OUTPUT DUAL RANGE; CROWBAROVERVOLTAGE PROTECTION |
| input_voltage_rating | 105.0 AC VOLTS MINIMUM AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
| output_current_rating | 0.0 DC AMPERES MINIMUM AND 1.5 DC AMPERES MAXIMUM FIRST POWER OUTPUT |
| output_voltage_rating | 0.0 DC VOLTS MINIMUM AND 40.0 DC VOLTS MAXIMUM SECOND POWER OUTPUT |
| end_item_identification | AN/URC-117 GROUND WAVE EMERGENCY NETWORK (GWEN) |
| ventilation_design_type | CONVECTION |
| operating_ambient_temp_range | +0.1 TO 55.0 CELSIUS DEGC |
| electrical_power_source_relationship | OPERATING |
| NSN | 6130-00-463-4638 |
| OVERALL LENGTH | 13.687 INCHES NOMINAL IN |
| OVERALL WIDTH | 8.500 INCHES NOMINAL IN |
| INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
| OPERATING AMBIENT TEMP RANGE | +0.1 TO 55.0 CELSIUS DEGC |
| SPECIAL FEATURES | SINGLE OUTPUT DUAL RANGE; CROWBAROVERVOLTAGE PROTECTION |
| OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM AND 1.5 DC AMPERES MAXIMUM FIRST POWER OUTPUT |
| OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM AND 20.0 DC VOLTS MAXIMUM FIRST POWER OUTPUT |
| OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM AND 0.75 DC AMPERES MAXIMUM SECOND POWER OUTPUT |
| OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM AND 40.0 DC VOLTS MAXIMUM SECOND POWER OUTPUT |
| VENTILATION DESIGN TYPE | CONVECTION |