Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

The HP3-ETXBFE98 is a the manufacturer industrial component. Key specifications include color: WHITE FIRST POSITION COVER SINGLE CONDUCTOR, material: PLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR, tracer_color: GRAY/GREY FIRST TRACER SINGLE CONDUCTOR, conductor_form: STRANDED SINGLE CONDUCTOR, surface_treatment: SILVER CORE CONDUCTOR SINGLE CONDUCTOR, round_conductor_size: 22 AWG SINGLE CONDUCTOR. This product is currently in active production with full OEM support.

This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-01-230-9323, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL HP3-ETXBFE98
NSN: 6145-01-230-9323
FSC: 6145
CAGE: 1P787 — NATIONAL ELECTRICAL MFRS ASSN DBA NEMA (USA)
SPECIFICATIONS
colorWHITE FIRST POSITION COVER SINGLE CONDUCTOR
materialPLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
tracer_colorGRAY/GREY FIRST TRACER SINGLE CONDUCTOR
conductor_formSTRANDED SINGLE CONDUCTOR
surface_treatmentSILVER CORE CONDUCTOR SINGLE CONDUCTOR
round_conductor_size22 AWG SINGLE CONDUCTOR
cross-sectional_shape_styleROUND
specification/standard_data81349-MIL-W-16878/6 GOVERNMENT SPECIFICATION
strand_quantity_per_conductor7 SINGLE CONDUCTOR
cross_section_outside_diameter0.042 INCHES NOMINAL IN
NSN6145-01-230-9323
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: HP3-ETXBFE98 · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
CROSS SECTION OUTSIDE DIAMETER: 0.042 INCHES NOMINAL IN
MATERIAL: COPPER CORE CONDUCTOR SINGLE CONDUCTOR
CONDUCTOR FORM: STRANDED SINGLE CONDUCTOR
COLOR: WHITE FIRST POSITION COVER SINGLE CONDUCTOR
SPECIFICATION/STANDARD DATA: 81349-MIL-W-16878/6 GOVERNMENT SPECIFICATION
SURFACE TREATMENT: SILVER CORE CONDUCTOR SINGLE CONDUCTOR
CROSS-SECTIONAL SHAPE STYLE: ROUND
TEST DATA DOCUMENT: 81349-MIL-W-16878 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TECHNICAL CHARACTERISTICS (FLIS)
CROSS SECTION OUTSIDE DIAMETER0.042 INCHES NOMINAL IN
MATERIALCOPPER CORE CONDUCTOR SINGLE CONDUCTOR
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
COLORWHITE FIRST POSITION COVER SINGLE CONDUCTOR
SPECIFICATION/STANDARD DATA81349-MIL-W-16878/6 GOVERNMENT SPECIFICATION
SURFACE TREATMENTSILVER CORE CONDUCTOR SINGLE CONDUCTOR
CROSS-SECTIONAL SHAPE STYLEROUND
TEST DATA DOCUMENT81349-MIL-W-16878 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
STRAND QUANTITY PER CONDUCTOR7 SINGLE CONDUCTOR
MATERIALPLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
VERIFIED SUBSTITUTES & CROSS-REFERENCES 15
ES7751-22EJ926Upgraded Successor
successor cross-reference
successor
M22759/11-22-926Upgraded Successor
successor cross-reference
successor
ES7751-22EJ967Upgraded Successor
successor cross-reference
successor
AS22759/11Upgraded Successor
successor cross-reference
successor
NEMA HP3Upgraded Successor
successor cross-reference
successor
SAE-AS22759/11Upgraded Successor
successor cross-reference
successor
LIFECYCLE
StatusACTIVE
AvailabilityOEM and secondary market
RoHS CompliantEAR99Not HAZMAT
Ready to buy HP3-ETXBFE98?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is HP3-ETXBFE98?
HP3-ETXBFE98 is a HP3-ETXBFE98. It is classified as a MRO (MRO_GENERAL).
What parts can replace HP3-ETXBFE98?
There are 15 known substitutes for HP3-ETXBFE98: ES7751-22EJ926, M22759/11-22-926, ES7751-22EJ967 and 12 more. Substitute compatibility should be verified for your specific system.
What is the NSN for HP3-ETXBFE98?
HP3-ETXBFE98 is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-01-230-9323. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — HP3-ETXBFE98