HD12-6.8-A: POWER SUPPLY.
The POWER SUPPLY is a the manufacturer power supply unit built for continuous operation in enterprise server and storage platforms. This part is cataloged in the U.S. Government catalog under NSN 6130-01-240-1177, indicating validated use in U.S.
government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.
| NSN | 6130-01-240-1177 |
| OVERALL HEIGHT | 2.750 INCHES NOMINAL IN |
| OVERALL LENGTH | 9.000 INCHES NOMINAL IN |
| OVERALL WIDTH | 4.870 INCHES NOMINAL IN |
| INPUT VOLTAGE RATING | 100.0 AC VOLTS MINIMUM AND 240.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| SPECIAL FEATURES | LINE REGULATION=+ OR - 0.05 PERCENT FOR A 10 PERCENT LINE CHANGE; LOAD REGULATION=+ OR - 0.05 PERCENT FOR A 50 PERCENT LOAD CHANGE; OUTPUT RIPPLE=2V-15V UNITS ARE 5.0MV PK-PK MAX.,20V-200V UNITS ARE 0.02 PERCENT PK-PK MAX.;TRANSIENT RESPONSE=50 SEC. FOR A 50 PERCENT LOAD CHANGE; SHORT CIRCUIT AND OVERLOAD PROTECTION=AUTOMATIC CURRENT LIMIT/FOLDBACK; REMOTE SENSING=OPEN SENSE LEAD PROTECTION BUILT-IN; STABILITY=+0.3 PERCENT FOR 24 HR. PERIOD AFTER 1 HR. WARM-UP; TEMP. RATING=0-50 DEG. C. FULL-RATED,DERATED LINEARLY TO 40 PERCENT AT 70 DEG. C.; TEMP. COEFFICIENT=+ OR - 0.03 PERCENT/DEG. C. MAX.; EFFICIENCY=5V UNITS ARE 45 PERCENT,12V AND 15V UNITS ARE 55 PERCENT,20V AND 24V UNITS ARE 60 PERCENT V |