GC18A118P — CABLE,SPECIAL PURPOSE,ELECTRICAL

✓ Government record, cited
— · WIRE CABLE
PRODUCT OVERVIEW

GC18A118P: CABLE,SPECIAL PURPOSE,ELECTRICAL.

CABLE,SPECIAL PURPOSE,ELECTRICAL. Key specifications include material: COPPER FIRST POSITION SHIELD BRAID METALLIC CABLE, temp_rating: -55.0 CELSIUS AND 200.0 CELSIUS DEGC, conductor_form: STRANDED SINGLE CONDUCTOR, round_conductor_size: 18 AWG SINGLE CONDUCTOR, cross-sectional_shape_style: ROUND, strand_quantity_per_conductor: 19 SINGLE CONDUCTOR. This part is cataloged in the U.S.

Government catalog under NSN 6145-01-502-3128, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
GC18A118P
NSN: 6145-01-502-3128
FSC: 6145 — Wire and Cable, Electrical
CAGE: 26512 — NORTHROP GRUMMAN SYSTEMS CORPORATION (USA)
SPECIFICATIONS
materialCOPPER FIRST POSITION SHIELD BRAID METALLIC CABLE
temp_rating-55.0 CELSIUS AND 200.0 CELSIUS DEGC
conductor_formSTRANDED SINGLE CONDUCTOR
conductor_quantity1
round_conductor_size18 AWG SINGLE CONDUCTOR
cross-sectional_shape_styleROUND
strand_quantity_per_conductor19 SINGLE CONDUCTOR
cross_section_outside_diameter0.114 INCHES NOMINAL IN
NSN6145-01-502-3128
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: GC18A118P · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
•
ROUND CONDUCTOR SIZE: 18 AWG SINGLE CONDUCTOR
•
TEMP RATING: -55.0 CELSIUS AND 200.0 CELSIUS DEGC
•
CONDUCTOR QUANTITY: 1
•
CROSS-SECTIONAL SHAPE STYLE: ROUND
•
CONDUCTOR FORM: STRANDED SINGLE CONDUCTOR
•
STRAND QUANTITY PER CONDUCTOR: 19 SINGLE CONDUCTOR
•
CROSS SECTION OUTSIDE DIAMETER: 0.114 INCHES NOMINAL IN
•
MATERIAL: PLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
TYPICAL APPLICATIONS
  • Server Internal Cabling
  • Data Center Cable Infrastructure
  • SAS/SATA Drive Connectivity
TECHNICAL CHARACTERISTICS
ROUND CONDUCTOR SIZE18 AWG SINGLE CONDUCTOR
TEMP RATING-55.0 CELSIUS AND 200.0 CELSIUS DEGC
CONDUCTOR QUANTITY1
CROSS-SECTIONAL SHAPE STYLEROUND
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 SINGLE CONDUCTOR
CROSS SECTION OUTSIDE DIAMETER0.114 INCHES NOMINAL IN
MATERIALPLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
MATERIALCOPPER CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALPLASTIC POLYTETRAFLUOROETHYLENE SECOND POSITION JACKET CABLE
OTHER ITEMS IN FSC 6145 — Wire and Cable, Electrical
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6145-00-000-0090 6145-00-000-0095 6145-00-001-1281 6145-00-001-3002 6145-00-001-4504 6145-00-001-5158 6145-00-001-5159 6145-00-001-5160
SUBSTITUTES & CROSS-REFERENCES

No substitute or cross-reference records for this part.

LIFECYCLE
NSN statusActive· U.S. Government catalog
No demilitarization required
Ready to buy GC18A118P?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is GC18A118P?
GC18A118P is a CABLE,SPECIAL PURPOSE,ELECTRICAL.
What is the NSN for GC18A118P?
GC18A118P is cataloged in the U.S. Government catalog under NSN 6145-01-502-3128. This indicates validated use in U.S. government and defense supply chains.