G138-256-009: FILTER,BAND PASS.
The FILTER,BAND PASS is a the manufacturer industrial component. Key specifications include inclosure_type: ENCASED, operating_temp_range: +0.0 TO 85.0 CELSIUS DEGC, load_impedance_per_function: 2.7 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED, reference_frequency_per_function: 3.681 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED, frequency_band_width_per_function: 1.8405 KILOHERTZ BLANK AND 5.5215 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED, source_impedance_rating_per_function: 2.7 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED. This part is cataloged in the U.S.
Government catalog under NSN 5915-00-243-9301, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| inclosure_type | ENCASED |
| operating_temp_range | +0.0 TO 85.0 CELSIUS DEGC |
| load_impedance_per_function | 2.7 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| reference_frequency_per_function | 3.681 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| frequency_band_width_per_function | 1.8405 KILOHERTZ BLANK AND 5.5215 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| source_impedance_rating_per_function | 2.7 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| specified_frequencies_of_discrimination_per_function | 920.25 HERTZ BLANK AND 1.8405 KILOHERTZ BLANK AND 5.5215 KILOHERTZ BLANK AND 7.362 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| insertion_loss_at_reference_frequency_per_function_in_decibels | 3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| discrimination_at_specified_frequencies_per_function_in_decibels | 25.0 NOMINAL BLANK AND 0.1 MAXIMUM BLANK FIRST FUNCTION |
| NSN | 5915-00-243-9301 |
| REFERENCE FREQUENCY PER FUNCTION | 3.681 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| INCLOSURE TYPE | ENCASED |
| SOURCE IMPEDANCE RATING PER FUNCTION | 2.7 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 25.0 NOMINAL BLANK AND 0.1 MAXIMUM BLANK FIRST FUNCTION |
| FREQUENCY BAND WIDTH PER FUNCTION | 1.8405 KILOHERTZ BLANK AND 5.5215 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| OPERATING TEMP RANGE | +0.0 TO 85.0 CELSIUS DEGC |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| LOAD IMPEDANCE PER FUNCTION | 2.7 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 920.25 HERTZ BLANK AND 1.8405 KILOHERTZ BLANK AND 5.5215 KILOHERTZ BLANK AND 7.362 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |