PartsTable
Technical Data Sheet
CH10240 ✓ Verified by PartsTable
· MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Verify manufacturer and server generation compatibility Check if Option PN or Spare PN — same part, different channel
Confirm exact part number — similar PNs may be different parts
PRODUCT OVERVIEW

The CIRCUIT BREAKER is a the manufacturer industrial component. Key specifications include material: PLASTIC CASE, body_style: MULTIPOLE-MULTIPLE ACTUATOR TYPE, body_width: 1.464 INCHES MINIMUM AND 1.496 INCHES MAXIMUM IN, body_height: 2.312 INCHES NOMINAL IN, body_length: 2.987 INCHES MINIMUM AND 3.013 INCHES MAXIMUM IN, boss_height: 0.188 INCHES NOMINAL IN. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5925-00-233-9255, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL CH10240
NSN: 5925-00-233-9255
FSC: 5925
CAGE: 55841 — EATON CORP ELECTRICAL CONSTRUCTION EQUIPMENT OPNS (USA)
SPECIFICATIONS
materialPLASTIC CASE
body_styleMULTIPOLE-MULTIPLE ACTUATOR TYPE
body_width1.464 INCHES MINIMUM AND 1.496 INCHES MAXIMUM IN
body_height2.312 INCHES NOMINAL IN
body_length2.987 INCHES MINIMUM AND 3.013 INCHES MAXIMUM IN
boss_height0.188 INCHES NOMINAL IN
reset_methodMANUAL
storage_typeGENERAL PURPOSE WAREHOUSE
pole_quantity2
fragility_factorMODERATELY RUGGED
actuator_functionTRIP-RESET
frequency_in_hertz60.0 ALL LOCATIONS
NSN5925-00-233-9255
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available CIRCUIT BREAKER TITLE COMPONENT PN CH10240 MFR CIRCUIT BREAKER
KEY FEATURES
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
TECHNICAL CHARACTERISTICS (FLIS)
RESET METHODMANUAL
TRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE40.0 AMPERES AC ALL LOCATIONS
FREQUENCY IN HERTZ60.0 ALL LOCATIONS
TRIP RELEASE METHODTHERMAL-MAGNETIC ALL LOCATIONS
TEST DATA DOCUMENT81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
VERIFIED SUBSTITUTES & CROSS-REFERENCES 13
2532752Interchangeable
interchangeable cross-reference
interchangeable
P-272Interchangeable
interchangeable cross-reference
interchangeable
PF370Interchangeable
interchangeable cross-reference
interchangeable
W-C-375/6Interchangeable
interchangeable cross-reference
interchangeable
WC375/06-002Interchangeable
interchangeable cross-reference
interchangeable
CH230Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy CH10240?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is CH10240?
CH10240 is a CIRCUIT BREAKER. It is classified as a MRO (MRO_GENERAL).
What parts can replace CH10240?
There are 13 known substitutes for CH10240: 2532752, P-272, PF370 and 10 more. Substitute compatibility should be verified for your specific system.
Is CH10240 still available?
CH10240 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — CH10240