C5075979-29: INSULATION SLEEVING,ELECTRICAL,S.
INSULATION SLEEVING,ELECTRICAL,S. Key specifications include material: PLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED, flexibility: SEMIRIGID, temp_rating: -55.0 CELSIUS DEGC, environmental_protection: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT, main_body_overall_length: 4.620 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN, main_body_wall_thickness: 0.080 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN. This part is cataloged in the U.S.
Government catalog under NSN 5970-01-191-4906, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| material | PLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED |
| flexibility | SEMIRIGID |
| temp_rating | -55.0 CELSIUS DEGC |
| environmental_protection | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
| main_body_overall_length | 4.620 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| main_body_wall_thickness | 0.080 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| minimum_tensile_strength | 1500 POUNDS PER SQUARE INCH LBS |
| main_body_inside_diameter | 1.000 INCHES MINIMUM AS SUPPLIED IN |
| first_branch_wall_thickness | 0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| third_branch_wall_thickness | 0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| first_branch_inside_diameter | 0.220 INCHES MINIMUM AS SUPPLIED IN |
| fourth_branch_wall_thickness | 0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| NSN | 5970-01-191-4906 |
| THIRD BRANCH INSIDE DIAMETER | 0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| THIRD BRANCH INSIDE DIAMETER | 0.220 INCHES MINIMUM AS SUPPLIED IN |
| TEMP RATING | -55.0 CELSIUS DEGC |
| SECOND BRANCH INSIDE DIAMETER | 0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| SECOND BRANCH INSIDE DIAMETER | 0.220 INCHES MINIMUM AS SUPPLIED IN |
| THIRD BRANCH WALL THICKNESS | 0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| FLEXIBILITY | SEMIRIGID |
| MATERIAL DOCUMENT AND CLASSIFICATION | RT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED |
| DISTANCE FROM CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| FOURTH BRANCH INSIDE DIAMETER | 0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
No substitute or cross-reference records for this part.