The POWER SUPPLY is a the manufacturer power supply unit built for continuous operation in enterprise server and storage platforms. Key specifications include input_phase: SINGLE SINGLE OPERATING POWER RQMT, output_phase: SINGLE MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS, overall_width: 90.0 MILLIMETERS NOMINAL MM, overall_height: 150.0 MILLIMETERS NOMINAL MM, overall_length: 330.0 MILLIMETERS NOMINAL MM, battery_location: INTERNAL. This product is currently in active production with full OEM support.
This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6130-01-465-1969, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| input_phase | SINGLE SINGLE OPERATING POWER RQMT |
| output_phase | SINGLE MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| overall_width | 90.0 MILLIMETERS NOMINAL MM |
| overall_height | 150.0 MILLIMETERS NOMINAL MM |
| overall_length | 330.0 MILLIMETERS NOMINAL MM |
| battery_location | INTERNAL |
| features_provided | BATTERY CHARGER AND CALIBRATED OUTPUT SIGNAL AND CIRCUIT BREAKER AND CIRCUIT OVERLOAD PROTECTION DEVICE AND EMI FILTER AND INPUT VOLTAGE RANGE SWITCH AND OVER CURRENT PROTECTOR AND VOLTAGE ADJUSTMENT |
| installation_design | BENCH |
| output_control_type | CURRENT LIMIT AND VOLTAGE ADJUSTMENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| input_voltage_rating | 240.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
| battery_recovery_time | 300.0 |
| output_current_rating | 500.0 AC VOLT-AMPERE NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| NSN | 6130-01-465-1969 |
| OVERALL LENGTH | 330.0 MILLIMETERS NOMINAL MM |
| INSTALLATION DESIGN | BENCH |
| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| MAXIMUM OPERATING ALTITUDE RATING | 3000.0 METERS |
| FREQUENCY REGULATION PERCENT | 0.5 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| SPECIAL FEATURES | INPUT VOLTAGE ADJUSTABLE IN FIVE INCREMENTS FROM A HIGH OF 220.0 TO 240.0 VAC, GREATER THAN 196.0 VAC, GREATER THAN 184.0 VAC, GREATER THAN 172.0 VAC, TO A LOW OF 160.0 VAC TO COMPENSA TE FOR BROWNOUT CONDITIONS; INPUT LINEUSES AN IEC 320 MALE APPLIANCE COUPLER; OPTION SWITCHES ALLOW FOR CUSTOMIZATION OF TRANSFER VOLTAGE (ON BATTERY) IN A STEPPED APPROXIMATION TO SINE WAVE AT 225.0 VAC PLUS OR MINUS 5 PERCENT, SET ALARM, AND CONTROL OUTPUT FREQUENCY SETTINGS; UNIT HAS 4 IEC FEMALE APPLIANCE COUPLERS; AMBIENT OPERATING HUMIDITY PLUS 0.0 TO 95.0 PERCENT (NON-CONDENSING); HOT SWAPPABLE USER-REPLACEABLE BATTERIES; WEIGHS 7.0 KG; LOW VOLTAGE DIRECTIVE 73/23/EEC, GS LICENSES BY VDE PER STANDARD EN60950 AND EN50091; EMC DIRECTIVE 89/336/EEC, C-TICK APPROVED, EN5022 (CISPR22) AND EN50082-1 VAC |
| FEATURES PROVIDED | BATTERY CHARGER AND CALIBRATED OUTPUT SIGNAL AND CIRCUIT BREAKER AND CIRCUIT OVERLOAD PROTECTION DEVICE AND EMI FILTER AND INPUT VOLTAGE RANGE SWITCH AND OVER CURRENT PROTECTOR AND VOLTAGE ADJUSTMENT |
| OUTPUT CONNECTION QUANTITY | 4 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| BATTERY FEATURE AND TYPE | RECHARGEABLE LEAD ACID CELL |
| POWER SUPPLIES PROGRAMMED PER SYSTEM | 4 |