PRODUCT OVERVIEW

The CIRCUIT BREAKER is a the manufacturer industrial component. Key specifications include material: PLASTIC CASE, body_style: SINGLE POLE TYPE, body_width: 1.000 INCHES MAXIMUM IN, body_height: 2.719 INCHES NOMINAL IN, body_length: 2.875 INCHES NOMINAL IN, boss_height: 0.187 INCHES NOMINAL IN. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5925-00-319-2866, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL BAB1030
NSN: 5925-00-319-2866
FSC: 5925
CAGE: 89946 — EATON CORPORATION DBA EATON INOAC (USA)
SPECIFICATIONS
materialPLASTIC CASE
body_styleSINGLE POLE TYPE
body_width1.000 INCHES MAXIMUM IN
body_height2.719 INCHES NOMINAL IN
body_length2.875 INCHES NOMINAL IN
boss_height0.187 INCHES NOMINAL IN
reset_methodMANUAL
storage_typeGENERAL PURPOSE WAREHOUSE
pole_quantity1
actuator_functionTRIP-RESET
frequency_in_hertz60.0 SINGLE LOCATION
mounting_slot_width0.562 INCHES NOMINAL IN
NSN5925-00-319-2866
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available CIRCUIT BREAKER TITLE COMPONENT PN BAB1030 MFR CIRCUIT BREAKER
KEY FEATURES
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL-MAGNETIC SINGLE LOCATION
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
TERMINAL TYPE AND QUANTITY: 1 COMPRESSION AND 1 TAB, SOLDER LUG
TECHNICAL CHARACTERISTICS (FLIS)
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT10.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS10000.0 AC SINGLE LOCATION
TRIP RELEASE METHODTHERMAL-MAGNETIC SINGLE LOCATION
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC ALL LOCATIONS
TERMINAL TYPE AND QUANTITY1 COMPRESSION AND 1 TAB, SOLDER LUG
ACTUATOR FUNCTIONTRIP-RESET
TRIP RELEASE AMBIENT TEMP RATING40.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
VERIFIED SUBSTITUTES & CROSS-REFERENCES 5
E42Interchangeable
interchangeable cross-reference
interchangeable
BA1030UInterchangeable
interchangeable cross-reference
interchangeable
2000030Interchangeable
interchangeable cross-reference
interchangeable
BA1030Interchangeable
Same NIIN cross-reference
interchangeable
QNBL1030Interchangeable
Same NIIN cross-reference
interchangeable
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy BAB1030?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is BAB1030?
BAB1030 is a CIRCUIT BREAKER. It is classified as a MRO (MRO_GENERAL).
What parts can replace BAB1030?
There are 5 known substitutes for BAB1030: E42, BA1030U, 2000030 and 2 more. Substitute compatibility should be verified for your specific system.
Is BAB1030 still available?
BAB1030 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — BAB1030