AP8958 — POWER STRIP,ELECTRICAL OUTLET

✓ Government record, cited
APC · WIRE CABLE
PRODUCT OVERVIEW

AP8958: POWER STRIP,ELECTRICAL OUTLET.

APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure This part is cataloged in the U.S. Government catalog under NSN 6150-01-661-3564, indicating validated use in U.S. government and defense logistics supply chains.

WHERE IT FITS
AP8958
NSN: 6150-01-661-3564
FSC: 6150 — Miscellaneous Electric Power and Distribution Equipment
CAGE: 0MG77 — SCHNEIDER ELECTRIC IT CORPORATION DBA A P S SALES & SERVICE DIV SCHNEIDER ELECTRIC IT CORP. (USA)
SPECIFICATIONS
outlet_typeSWITCHED
overall_width2.2 INCHES MINIMUM IN
overall_height38.9 INCHES MINIMUM IN
overall_length38.9 INCHES NOMINAL IN
mounting_methodRACK
features_providedCABLE ASSEMBLY
frequency_in_hertz60.0
mating_end_quantity8
current_rating_in_amps16.0
overload_rating_in_amps60.0 MAXIMUM
current_interrupting_capacity16.0 AMPERES MAXIMUM
NSN6150-01-661-3564
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: AP8958 · APC ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
•
FREQUENCY IN HERTZ: 60.0
•
CURRENT INTERRUPTING CAPACITY: 16.0 AMPERES MAXIMUM
•
MATING END QUANTITY: 8
•
MOUNTING METHOD: RACK
•
OUTLET TYPE: SWITCHED
TECHNICAL CHARACTERISTICS
OVERALL HEIGHT38.9 INCHES MINIMUM IN
FREQUENCY IN HERTZ60.0
CURRENT INTERRUPTING CAPACITY16.0 AMPERES MAXIMUM
MATING END QUANTITY8
MOUNTING METHODRACK
OVERALL LENGTH38.9 INCHES NOMINAL IN
OVERALL WIDTH2.2 INCHES MINIMUM IN
OUTLET TYPESWITCHED
FEATURES PROVIDEDCABLE ASSEMBLY
OVERLOAD RATING IN AMPS60.0 MAXIMUM
OTHER ITEMS IN FSC 6150 — Miscellaneous Electric Power and Distribution Equipment
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6150-00-000-0125 6150-00-000-0174 6150-00-000-0176 6150-00-000-0178 6150-00-000-0179 6150-00-000-0180 6150-00-001-1272 6150-00-001-1522
SUBSTITUTES & CROSS-REFERENCES

No substitute or cross-reference records for this part.

LIFECYCLE
NSN statusActive· U.S. Government catalog
No demilitarization required
Ready to buy AP8958?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is AP8958?
AP8958 is a POWER STRIP,ELECTRICAL OUTLET manufactured by APC.
What is the NSN for AP8958?
AP8958 is cataloged in the U.S. Government catalog under NSN 6150-01-661-3564. This indicates validated use in U.S. government and defense supply chains.