A8409900: INVERTER,POWER,STATIC.
The INVERTER,POWER,STATIC is a the manufacturer industrial component. This part is cataloged in the U.S. Government catalog under NSN 6130-01-504-5885, indicating validated use in U.S.
government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.
| NSN | 6130-01-504-5885 |
| OVERALL HEIGHT | 69.9 MILLIMETERS NOMINAL MM |
| OUTPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL FIRST POWER OUTPUT |
| OUTPUT VOLTAGE RATING | 26.0 AC VOLTS NOMINAL SECOND POWER OUTPUT |
| OVERALL LENGTH | 177.8 MILLIMETERS NOMINAL MM |
| OVERALL WIDTH | 127.0 MILLIMETERS NOMINAL MM |
| INPUT VOLTAGE RATING | 24.0 DC VOLTS MINIMUM AND 32.0 DC VOLTS MAXIMUM SECOND OPERATING POWER RQMT |
| INPUT VOLTAGE RATING | 28.0 DC VOLTS NOMINAL FIRST OPERATING POWER RQMT |
| MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET FT |
| OPERATING AMBIENT TEMP RANGE | -55.0 TO 71.0 CELSIUS DEGC |
| SPECIAL FEATURES | OUTPUT CONFIGURATION MONOPHASE SINEWAVE; EFFICIENCY 75 PCT NOMINAL; UNIT HAS REVERSE POLARITY PROTECTION; FREQUENCY MONITOR AUTOMATICALLY SHUTS THE INVERTER OFF SHOULD THE FREQUENCY DRIFT BELOW 370 HZ OR ABOVE 430 HZ; FAULTMONITOR PROVIDES 27 VDC OUTPUT AT 100 MA TO AN ANNUNCIATOR DEVICE UNDER NORMAL CONDITION; NO POWER IS AVAILABLE UNDER FAULT CONDITIONS; COOLING HI-REL BLOWER; ENVIRONMENTAL CONDITIONS RFI EMISSION MEETS RTCA DO-160A CAT Z; MATING CONNECTOR MS3476L14-9S VDC |