The TRANSFORMER,POWER is a the manufacturer industrial component. Key specifications include body_length: 0.500 INCHES MAXIMUM IN, inclosure_type: FULLY INCLOSED, mounting_method: THREADED HOLE(S) SINGLE GROUP, frequency_rating: 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT, overall_diameter: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN, nominal_thread_size: 0.112 INCHES SINGLE GROUP IN. This product is currently in active production with full OEM support.
This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5950-01-348-7902, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| body_length | 0.500 INCHES MAXIMUM IN |
| inclosure_type | FULLY INCLOSED |
| mounting_method | THREADED HOLE(S) SINGLE GROUP |
| frequency_rating | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| overall_diameter | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN |
| nominal_thread_size | 0.112 INCHES SINGLE GROUP IN |
| winding_power_rating | 5.7 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
| reliability_indicator | NOT ESTABLISHED |
| maximum_operating_temp | 125.0 CELSIUS DEGC |
| thread_series_designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| winding_operating_current | 75.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| winding_operating_voltage | 34.00 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| NSN | 5950-01-348-7902 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND FUNGUS RESISTANT AND SALT SPRAY RESISTANT AND VIBRATION RESISTANT |
| WINDING OPERATING CURRENT | 75.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| MAXIMUM OPERATING TEMP | 125.0 CELSIUS DEGC |
| WINDING POWER RATING | 5.7 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
| TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
| MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP IN |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |