PRODUCT OVERVIEW

900511-003: CIRCUIT BREAKER.

The CIRCUIT BREAKER is a the manufacturer industrial component. Key specifications include material: PLASTIC CASE, body_style: MULTIPOLE-MULTIPLE ACTUATOR TYPE, body_width: 2.250 INCHES MAXIMUM IN, body_length: 2.490 INCHES NOMINAL IN, boss_height: 0.150 INCHES NOMINAL IN, reset_method: MANUAL. This part is cataloged in the U.S.

Government catalog under NSN 5925-01-374-7002, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO→ MRO_GENERAL→ 900511-003
NSN: 5925-01-374-7002
FSC: 5925 — Circuit Breakers
CAGE: 63516 — L3HARRIS TECHNOLOGIES, INC. DBA L3HARRIS TECHNOLOGIES DIV SAS1 (USA)
SPECIFICATIONS
materialPLASTIC CASE
body_styleMULTIPOLE-MULTIPLE ACTUATOR TYPE
body_width2.250 INCHES MAXIMUM IN
body_length2.490 INCHES NOMINAL IN
boss_height0.150 INCHES NOMINAL IN
reset_methodMANUAL
pole_quantity3
actuator_functionTRIP-RESET
frequency_in_hertz400.0 ALL LOCATIONS
nominal_thread_size0.138 INCHES IN
trip_release_methodMAGNETIC ALL LOCATIONS
circuit_protection_typeOVERCURRENT ALL LOCATIONS
NSN5925-01-374-7002
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available CIRCUIT BREAKER TITLE COMPONENT PN 900511-003 MFR CIRCUIT BREAKER
KEY FEATURES
•
RESET METHOD: MANUAL
•
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
•
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
•
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE(S)
•
ACTUATOR POSITION DESIGNATION: AT POLE ONE
•
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
•
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL IN
•
BODY STYLE: MULTIPOLE-MULTIPLE ACTUATOR TYPE
TECHNICAL CHARACTERISTICS
RESET METHODMANUAL
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE(S)
ACTUATOR POSITION DESIGNATIONAT POLE ONE
FREQUENCY IN HERTZ400.0 ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.750 INCHES NOMINAL IN
BODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0 ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
OTHER ITEMS IN FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277 5925-00-001-2809 5925-00-001-3838 5925-00-001-5748 5925-00-001-5926 5925-00-001-5938 5925-00-001-5942 5925-00-001-5977
SUBSTITUTES & CROSS-REFERENCES 1
APL-111-1-42-752Same NSN cross-reference
Same NSN cross-reference
Also cataloged under this NSN
LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Insurance item — stocked against contingency demandNo demilitarization required
Ready to buy 900511-003?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 900511-003?
900511-003 is a CIRCUIT BREAKER. It is classified as a MRO (MRO_GENERAL).
What parts can replace 900511-003?
There is 1 known substitute for 900511-003: APL-111-1-42-752. Substitute compatibility should be verified for your specific system.
What is the NSN for 900511-003?
900511-003 is cataloged in the U.S. Government catalog under NSN 5925-01-374-7002. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 900511-003