8494068: CABLE ASSEMBLY,FIBER OPTIC.
The CABLE ASSEMBLY,FIBER OPTIC is a the manufacturer optical transceiver module designed for high-speed data center interconnects. Key specifications include overall_length: 81.00 INCHES IN, end_item_identification: AN-SLQ32X(V), part_name_assigned_by_controlling_agency: CABLE ASSEMBLY, FIBER OPTIC. This part is cataloged in the U.S.
Government catalog under NSN 6020-01-722-4909, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| overall_length | 81.00 INCHES IN |
| end_item_identification | AN-SLQ32X(V) |
| part_name_assigned_by_controlling_agency | CABLE ASSEMBLY, FIBER OPTIC |
| NSN | 6020-01-722-4909 |
| OVERALL LENGTH | 81.00 INCHES IN |
| SPECIAL TEST FEATURES | USE FN 8 TO BUILD UP CABLE DIAMETER UNDER FN 6 PRIOR TO SHRINKING; USE FN 8 TO BUILD UP CABLE DIAMETER UNDER BACKSHELL/CABLE CLAMP, TO ENSURE PROPER STRAIN RELIEF; AFTER ASSEMBLY THE CABLE SHALL BE TESTED FOR OPTICAL LOSS I/A/W EIA-455-171, (FOTP-171); OPTICAL LOSS SHALL NOT EXCEED 1.0DB AT 1550 NANOMETERS; ENSURE 29504 TERMINI ARE TESTED VIA INTERFEROMETER AND MEET REQUIREMENTS OUTLINED IN DEPARTMENT OF THE NAVY GUIDANCE DOCUMENT: METHOD TO MEASURE FERRULE END FACES, FIBER OPTIC CONNECTORS AND TERMINI (SER NUMBER 96315/067 DATED OCTOBER 31, 2003) DB |
| SPECIAL FEATURES | MARK I/A/W MIL-STD-130 AND SAE-AS81531, CONTRASTING COLOR, CHARACTERS .10 MINIMUM HIGH, PRIOR TO SHRINKING (OR .05 MINIMUM HIGH AFTER SHRINKING); MARKER SHALL BE LONGER THAN THE SPECIFIED MARKING, BY A MINIMUM OF 1 CHARACTER WIDTH, ON EACH SIDE OF THE MARKING; AN ACCEPTABLE ALTERNATE PART FOR FN 6 IS OKWOO*PVF225194WE2.5; IF ALTERNATE PART IS USED, MARKER SHALL BE OF SUFFICIENT LENGTH TO WRAP CABLE AND OVERLAP ITSELF BY APPROXIMATELY HALF THE CIRCUMFERENCE OF THE CABLE; ALL SPARE CONNECTOR CAVITIES SHALL BE POPULATED WITH DUMMY TERMINI FN 3; WHEN APPLYING HEAT TO THE INSULATION SLEEVING, DO NOT OVERHEAT THE OFCC; PROLONGED EXPOSURE OF THE OFCC TO TEMPERATURES ABOVE 160 DEGREES CELSIUS MAY DAMAGE THE OFCC JACKET; DISCONTINUE HEATING OF THE TUBING AND ALLOW THE JACKET TO COOL BEFORE REHEATING IF THE JACKET SHOWS SIGNS OF BUBBLING; COVER FN 7 WITH FN 6 OVERLAPPING FN 5 BY APPROXIMATELY .25-.50" |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | CABLE ASSEMBLY, FIBER OPTIC |
| END ITEM IDENTIFICATION | AN-SLQ32X(V) |
No substitute or cross-reference records for this part.