PartsTable
Technical Data Sheet
Download PDF

796542 — CABLE ASSEMBLY,SPECIAL PURPOSE,E

✓ Government record, cited
— · WIRE CABLE
PRODUCT OVERVIEW

796542: CABLE ASSEMBLY,SPECIAL PURPOSE,E.

CABLE ASSEMBLY,SPECIAL PURPOSE,E. Key specifications include material: COPPER CORE CONDUCTOR ALL CONDUCTORS, usage_design: TEST LEADS, binding_method: SLEEVE AND WIRE BOUND, termination_type: CONNECTOR SECOND END ALL CONDUCTORS, conductor_quantity: 12, cable_assembly_overall_length: 264.000 INCHES NOMINAL IN. This part is cataloged in the U.S.

Government catalog under NSN 6150-01-330-8981, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
796542
NSN: 6150-01-330-8981
FSC: 6150 — Miscellaneous Electric Power and Distribution Equipment
CAGE: 73030 — HAMILTON SUNDSTRAND CORPORATION DBA COLLINS AEROSPACE (USA)
SPECIFICATIONS
materialCOPPER CORE CONDUCTOR ALL CONDUCTORS
usage_designTEST LEADS
binding_methodSLEEVE AND WIRE BOUND
branch_quantity3
termination_typeCONNECTOR SECOND END ALL CONDUCTORS
conductor_quantity12
cable_assembly_overall_length264.000 INCHES NOMINAL IN
NSN6150-01-330-8981
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: 796542 · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
•
TERMINATION TYPE: CONNECTOR SECOND END ALL CONDUCTORS
•
BRANCH QUANTITY: 3
•
CABLE ASSEMBLY OVERALL LENGTH: 264.000 INCHES NOMINAL IN
•
USAGE DESIGN: TEST LEADS
•
CONDUCTOR QUANTITY: 12
•
MATERIAL: COPPER CORE CONDUCTOR ALL CONDUCTORS
TYPICAL APPLICATIONS
  • Server Internal Cabling
  • Data Center Cable Infrastructure
  • SAS/SATA Drive Connectivity
TECHNICAL CHARACTERISTICS
TERMINATION TYPECONNECTOR SECOND END ALL CONDUCTORS
TERMINATION TYPECONNECTOR FIRST END ALL CONDUCTORS
BRANCH QUANTITY3
CABLE ASSEMBLY OVERALL LENGTH264.000 INCHES NOMINAL IN
USAGE DESIGNTEST LEADS
CONDUCTOR QUANTITY12
SPECIAL FEATURES1 ADAPTER,CONN; 1 RING,SPLIT; 3 CAP,CONN; 2 RING,SPLIT; 2 BACKSHELL,CONN; 1 SOCKET,CHROMEL; 1 SOCKET,ALUMEL; 1 PIN,CHROMEL; 1 PIN,ALUMEL; 1 BREAKOUT; 3 PMT MARKER; A/R TUBING,HEATSHRINK; WIRE,ELEC,TW SH PR; BRAID,WIRE; TAPE,GLASS,LACING; U/O INSTL ASSY AGETS P/N AD56025; E/I AUTOMATIC GRD ENG TEST STAND AGETS P/N PWA52105
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
BINDING METHODSLEEVE AND WIRE BOUND
OTHER ITEMS IN FSC 6150 — Miscellaneous Electric Power and Distribution Equipment
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6150-00-000-0125 6150-00-000-0174 6150-00-000-0176 6150-00-000-0178 6150-00-000-0179 6150-00-000-0180 6150-00-001-1272 6150-00-001-1522
SUBSTITUTES & CROSS-REFERENCES 1
796542-2Reference document
Same NSN cross-reference
Reference document — Secondary reference
LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Terminal item — no further procurement; issued until stock is exhaustedNo demilitarization required
Ready to buy 796542?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 796542?
796542 is a CABLE ASSEMBLY,SPECIAL PURPOSE,E.
What parts can replace 796542?
There is 1 known substitute for 796542: 796542-2. Substitute compatibility should be verified for your specific system.
What is the NSN for 796542?
796542 is cataloged in the U.S. Government catalog under NSN 6150-01-330-8981. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 796542