PRODUCT OVERVIEW

The CIRCUIT BREAKER is a the manufacturer industrial component. Key specifications include material: PLASTIC CASE, body_style: MULTIPOLE-MULTIPLE ACTUATOR TYPE, body_width: 2.263 INCHES MINIMUM AND 2.283 INCHES MAXIMUM IN, body_length: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM IN, reset_method: MANUAL, storage_type: GENERAL PURPOSE WAREHOUSE. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5925-00-823-2346, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL 711575-022
NSN: 5925-00-823-2346
FSC: 5925
CAGE: 82577 — RAYTHEON COMPANY DBA RAYTHEON (USA)
SPECIFICATIONS
materialPLASTIC CASE
body_styleMULTIPOLE-MULTIPLE ACTUATOR TYPE
body_width2.263 INCHES MINIMUM AND 2.283 INCHES MAXIMUM IN
body_length2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM IN
reset_methodMANUAL
storage_typeGENERAL PURPOSE WAREHOUSE
pole_quantity3
bushing_length0.120 INCHES MINIMUM AND 0.140 INCHES MAXIMUM IN
fragility_factorMODERATELY RUGGED
actuator_functionTRIP-RESET
frequency_in_hertz400.0 ALL LOCATIONS
nominal_thread_size0.138 INCHES IN
NSN5925-00-823-2346
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available CIRCUIT BREAKER TITLE COMPONENT PN 711575-022 MFR CIRCUIT BREAKER
KEY FEATURES
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 7.25 AMPERES AC ALL LOCATIONS
NOMINAL THREAD SIZE: 0.138 INCHES IN
ACTUATOR POSITION DESIGNATION: AT EACH POLE
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.300 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC ALL LOCATIONS
TECHNICAL CHARACTERISTICS (FLIS)
TRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE7.25 AMPERES AC ALL LOCATIONS
NOMINAL THREAD SIZE0.138 INCHES IN
ACTUATOR POSITION DESIGNATIONAT EACH POLE
FREQUENCY IN HERTZ400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.300 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS3500.0 AC ALL LOCATIONS
TERMINAL TYPE AND QUANTITY6 TAB W/SCREW
MATERIALPLASTIC CASE
VERIFIED SUBSTITUTES & CROSS-REFERENCES 5
609-5Interchangeable
interchangeable cross-reference
interchangeable
155-3953-44Interchangeable
interchangeable cross-reference
interchangeable
57460Interchangeable
interchangeable cross-reference
interchangeable
3XAM17-3-120VAC400C54Interchangeable
Same NIIN cross-reference
interchangeable
74-101-10Interchangeable
Same NIIN cross-reference
interchangeable
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy 711575-022?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 711575-022?
711575-022 is a CIRCUIT BREAKER. It is classified as a MRO (MRO_GENERAL).
What parts can replace 711575-022?
There are 5 known substitutes for 711575-022: 609-5, 155-3953-44, 57460 and 2 more. Substitute compatibility should be verified for your specific system.
Is 711575-022 still available?
711575-022 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 711575-022