PartsTable
Technical Data Sheet
Download PDF

70124-1030 — RESISTOR,FIXED,WIRE WOUND,INDUCT

✓ Government record, cited
— · MRO · MRO_GENERAL
PRODUCT OVERVIEW

70124-1030: RESISTOR,FIXED,WIRE WOUND,INDUCT.

RESISTOR,FIXED,WIRE WOUND,INDUCT. Key specifications include body_length: 0.438 INCHES MINIMUM AND 0.562 INCHES MAXIMUM IN, body_diameter: 0.229 INCHES MINIMUM AND 0.281 INCHES MAXIMUM IN, cubic_measure: 0.018 CUBIC INCHES, terminal_type: WIRE LEAD, inclosure_type: ENCAPSULATED, terminal_length: 1.875 INCHES MINIMUM AND 2.125 INCHES MAXIMUM IN. This part is cataloged in the U.S.

Government catalog under NSN 5905-00-407-0133, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO→ MRO_GENERAL→ 70124-1030
NSN: 5905-00-407-0133
FSC: 5905 — Resistor
CAGE: 09691 — L3HARRIS MAS INC DIV L3HARRIS MAS INC. (CAN)
SPECIFICATIONS
body_length0.438 INCHES MINIMUM AND 0.562 INCHES MAXIMUM IN
body_diameter0.229 INCHES MINIMUM AND 0.281 INCHES MAXIMUM IN
cubic_measure0.018 CUBIC INCHES
terminal_typeWIRE LEAD
inclosure_typeENCAPSULATED
terminal_length1.875 INCHES MINIMUM AND 2.125 INCHES MAXIMUM IN
style_designatorAXIAL TERMINAL EACH END
electrical_resistance1.999 MEGOHMS
reliability_indicatorNOT ESTABLISHED
unpackaged_unit_weight2.0 GRAMS G
resistance_tolerance_in_percent-0.010 TO 0.010
ambient_temp_at_full_rated_power125.0 CELSIUS DEGC
NSN5905-00-407-0133
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available RESISTOR,FIXED,WIRE WOUND,INDUCT TITLE COMPONENT PN 70124-1030 MFR RESISTOR,FIXED,WIRE WO
KEY FEATURES
•
RESISTANCE TOLERANCE IN PERCENT: -0.010 TO 0.010
•
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS: -10.0 TO 10.0
•
BODY DIAMETER: 0.229 INCHES MINIMUM AND 0.281 INCHES MAXIMUM IN
•
ELECTRICAL RESISTANCE: 1.999 MEGOHMS
•
INCLOSURE TYPE: ENCAPSULATED
•
TERMINAL TYPE: WIRE LEAD
•
TERMINAL LENGTH: 1.875 INCHES MINIMUM AND 2.125 INCHES MAXIMUM IN
•
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS: -40.0 TO 71.0
TECHNICAL CHARACTERISTICS
RESISTANCE TOLERANCE IN PERCENT-0.010 TO 0.010
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-10.0 TO 10.0
BODY DIAMETER0.229 INCHES MINIMUM AND 0.281 INCHES MAXIMUM IN
ELECTRICAL RESISTANCE1.999 MEGOHMS
INCLOSURE TYPEENCAPSULATED
TERMINAL TYPEWIRE LEAD
TERMINAL LENGTH1.875 INCHES MINIMUM AND 2.125 INCHES MAXIMUM IN
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-40.0 TO 71.0
STYLE DESIGNATORAXIAL TERMINAL EACH END
POWER DISSIPATION RATING IN WATTS0.150 FREE AIR
OTHER ITEMS IN FSC 5905 — Resistor
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5905-00-000-0136 5905-00-000-0488 5905-00-000-8809 5905-00-000-8833 5905-00-000-9526 5905-00-001-1342 5905-00-001-1573 5905-00-001-2059
SUBSTITUTES & CROSS-REFERENCES 3
1923-1030Reference document
Same NSN cross-reference
Reference document — Advisory reference — outside the item-of-supply concept
1110-1030Reference document
Same NSN cross-reference
Reference document — Secondary reference
70126-1030Reference document
Same NSN cross-reference
Reference document — Secondary reference
LIFECYCLE
NSN statusActive· U.S. Government catalog
No demilitarization required
Ready to buy 70124-1030?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 70124-1030?
70124-1030 is a RESISTOR,FIXED,WIRE WOUND,INDUCT. It is classified as a MRO (MRO_GENERAL).
What parts can replace 70124-1030?
There are 3 known substitutes for 70124-1030: 1923-1030, 1110-1030, 70126-1030. Substitute compatibility should be verified for your specific system.
What is the NSN for 70124-1030?
70124-1030 is cataloged in the U.S. Government catalog under NSN 5905-00-407-0133. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 70124-1030