70120FN: RELAY,ELECTROMAGNETIC.

The RELAY,ELECTROMAGNETIC is a the manufacturer industrial component. Key specifications include duty_type: CONTINUOUS, time_delay: 1.00 MINUTES MINIMUM AND 10.00 MINUTES MAXIMUM ADJUSTABLE OPERATE TIME, storage_type: GENERAL PURPOSE WAREHOUSE, overall_width: 3.250 INCHES NOMINAL IN, overall_height: 3.090 INCHES MAXIMUM IN, overall_length: 4.520 INCHES NOMINAL IN. This part is cataloged in the U.S.

Government catalog under NSN 5945-01-332-1039, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
70120FN
NSN: 5945-01-332-1039
FSC: 5945 — Relays and Solenoids
CAGE: 89020 — TE CONNECTIVITY CORPORATION (USA)
SPECIFICATIONS
duty_typeCONTINUOUS
time_delay1.00 MINUTES MINIMUM AND 10.00 MINUTES MAXIMUM ADJUSTABLE OPERATE TIME
storage_typeGENERAL PURPOSE WAREHOUSE
coil_quantity1
overall_width3.250 INCHES NOMINAL IN
overall_height3.090 INCHES MAXIMUM IN
overall_length4.520 INCHES NOMINAL IN
fragility_factorMODERATELY RUGGED
winding_quantity1
arc_quenching_methodAIR
end_item_identificationOTHBWCRS
environmental_protectionSHOCK RESISTANT AND VIBRATION RESISTANT
NSN5945-01-332-1039
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available RELAY,ELECTROMAGNETIC TITLE COMPONENT PN 70120FN MFR RELAY,ELECTROMAGNETIC
KEY FEATURES
•
MOUNTING FACILITY TYPE AND QUANTITY: 6 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
•
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 480.0 AC AND 110.0 DC
•
FRAGILITY FACTOR: MODERATELY RUGGED
•
MOUNTING FACILITY PATTERN: RECTANGULAR SINGLE MOUNTING FACILITY
•
ARC QUENCHING METHOD: AIR
•
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH: 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
•
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 12.0 AMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD
TECHNICAL CHARACTERISTICS
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
OVERALL HEIGHT3.090 INCHES MAXIMUM IN
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS480.0 AC AND 110.0 DC
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING FACILITY PATTERNRECTANGULAR SINGLE MOUNTING FACILITY
ARC QUENCHING METHODAIR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE12.0 AMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD
DUTY TYPECONTINUOUS
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SUBSTITUTES & CROSS-REFERENCES 1
2530852PC26Reference document
Same NSN cross-reference
Reference document — Advisory reference — outside the item-of-supply concept
LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Normally procured from the manufacturer (OEM)No demilitarization required
Ready to buy 70120FN?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 70120FN?
70120FN is a RELAY,ELECTROMAGNETIC.
What parts can replace 70120FN?
There is 1 known substitute for 70120FN: 2530852PC26. Substitute compatibility should be verified for your specific system.
What is the NSN for 70120FN?
70120FN is cataloged in the U.S. Government catalog under NSN 5945-01-332-1039. This indicates validated use in U.S. government and defense supply chains.