The Transducer,motional Pickup, cataloged under National Stock Number 6695-01-466-4956, is classified within Federal Supply Class 6695 (Combination and Miscellaneous Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Advanced Technology Lab Uk Ltd. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6695-01-466-4956 |
| Primary Part Number | CL10-5 |
| Item Name | Transducer,motional Pickup |
| FSC / FSG | 6695 / 66 — Combination and Miscellaneous Instruments |
| Manufacturer | Advanced Technology Lab Uk Ltd |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| CL10-5 | Advanced Technology Lab Uk Ltd (GBR) |
| Reference | Meaning |
|---|---|
| CL10-5 | 3/9 Design control — primary reference Philips Ultrasound, Inc. Dba Philips Medical Systems |
NSN 6695-01-466-4956 is a Transducer,motional Pickup, manufactured by Advanced Technology Lab Uk Ltd, classified under FSC 6695, Combination and Miscellaneous Instruments. Status: active.
NSN 6695-01-466-4956 has 1 manufacturer part number on file: CL10-5 (Advanced Technology Lab Uk Ltd).
1 possible match (shared part number, not a government interchangeability claim): 6635-01-474-1209. Verify interchangeability with system specifications before substitution.
Key specifications for CL10-5: Special Features: INTRAOPERATIVE VASCULAR SURGERY SCANHEAD; 26 MM LINEAR FIELD OF VIEW; 32MM TISSUE PENETRATION; FREQUENCY RANGE 5 TO 10 MHZ; DOPPLER FREQUENCY 6 MHZ; 128 ELEMENTS; 4MM ELEVATION APERATURE; 0 TO 25MM ELEVATION FOCAL RANGE; USED FOR INTRAOPERATIVE VASCULAR EXAMS AND NON-SURGICAL SUPERFICIAL VASCULAR EXAMS MHz. 0 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.