The Calibration Set,secondary Refere, cataloged under National Stock Number 6695-01-461-9144, is classified within Federal Supply Class 6695 (Combination and Miscellaneous Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 1 specification, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6695-01-461-9144 |
| Item Name | Calibration Set,secondary Refere |
| FSC / FSG | 6695 / 66 — Combination and Miscellaneous Instruments |
| Status | ACTIVE |
| Supplementary Features | THE SGFC IS A COMPLETELY AUTOMATED CALIBRATION TRANSFER STANDARD SYS, DESIGNED FOR CALIBRATION OF GAS FLOW METERS. IT UTILIZES SONIC NOZZLES, TEMP,AND PRESSURE TRANSDUCERS; PNEUMATIC CONTROL VALVES AND A PERSONAL COMPUTER TO SET, MONITOR AND CONTROL CALIBRATOR FLOW RATE. THE SYS INCORPORATES TEMP, DEFFERENTIAL PRESSURE & PRESSURE TRANSOUCERS; ALONG WITH SPECIALIZED DATA ACQUISITION DEVICES FOR UUT ANLOG OR FREQUENCEY OUTPUTS FLOW-CAL SOFTWARE THATWILL CONTROL ALL OPERATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| FDI-SGFC-0250 | 3/9 Design control — primary reference Cox Flow Measurement Inc. Dba Flow Dynamics |
| FDI-SGFC-0250 | 5/9 Secondary reference Badger Meter, Inc. Div Cox Flow Measurement |
NSN 6695-01-461-9144 is a Calibration Set,secondary Refere, classified under FSC 6695, Combination and Miscellaneous Instruments. Status: active.
Key specifications for 6695-01-461-9144: Supplementary Features: THE SGFC IS A COMPLETELY AUTOMATED CALIBRATION TRANSFER STANDARD SYS, DESIGNED FOR CALIBRATION OF GAS FLOW METERS. IT UTILIZES SONIC NOZZLES, TEMP,AND PRESSURE TRANSDUCERS; PNEUMATIC CONTROL VALVES AND A PERSONAL COMPUTER TO SET, MONITOR AND CONTROL CALIBRATOR FLOW RATE. THE SYS INCORPORATES TEMP, DEFFERENTIAL PRESSURE & PRESSURE TRANSOUCERS; ALONG WITH SPECIALIZED DATA ACQUISITION DEVICES FOR UUT ANLOG OR FREQUENCEY OUTPUTS FLOW-CAL SOFTWARE THATWILL CONTROL ALL OPERATION; Special Features: FLOW RANGE: 0.0105 SCFM TO 250 SCFM; OPERATING FLUID TYPES: AIR NITROGEN; COMPENSATED FLUID TYPS: HELIUM, OXYGEN, CARBON DIOXIDE; OPERATING TEMPERATURE RANGE: FLOWING GAS STREM,60-90 DEG F. ELECTRONICS/TRANSDUCERS EVIRONMENT: 70 DEG PORM 20 DEG F; OUTPUTS: COMMUNICATIONS, RS-232C OR IEEE 488; DISPLAY: 20 CHARACTER X2 LINE; ACCURACY: PORM 0.35% READING @ 1 STANDARD DEVIATION. POWER REQUIREMENTS: 115VAC/60HZ/2AMP; AIR SUPPLY: 120 PSIA REGULATED SOURCE 250SCFM VAC. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.