Features
  • Indicator,temperature,thermocoup — FSC 6685
  • Mounting Facility Type and Quantity: 1 PANEL
  • Length: 7.000 INCHES NOMINAL IN
  • AC Voltage Rating: 115.0 VOLTS NOMINAL
  • Current Type: AC
  • Electrical Connection Quantity: 1
  • Supplementary Features: CHROMEL ALUMEL TYPE THERMOCOUPLE, CASE PER MS33639
  • Scale Range: +200.0 TO 1200.0 DEG CELSIUS SINGLE INDICATOR DEGREE CELSIUS
Identification
  • NSN: 6685-00-780-7787
  • NIIN: 007807787
  • FSC: 6685 — Pressure, Temperature, and Humidity Measuring and Controlling Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
General Description

The Indicator,temperature,thermocoup, cataloged under National Stock Number 6685-00-780-7787, is classified within Federal Supply Class 6685 (Pressure, Temperature, and Humidity Measuring and Controlling Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6685-00-780-7787
Item NameIndicator,temperature,thermocoup
FSC / FSG6685 / 66 — Pressure, Temperature, and Humidity Measuring and Controlling Instruments
StatusACTIVE
Mounting Facility Type and Quantity1 PANEL
Length7.000 INCHES NOMINAL IN
AC Voltage Rating115.0 VOLTS NOMINAL
Current TypeAC
Electrical Connection Quantity1
Supplementary FeaturesCHROMEL ALUMEL TYPE THERMOCOUPLE, CASE PER MS33639
Scale Range+200.0 TO 1200.0 DEG CELSIUS SINGLE INDICATOR DEGREE CELSIUS
Diameter2.000 INCHES NOMINAL IN
Dial Outside Diameter2.000 INCHES NOMINAL IN
Pointer TypeINDICATING SINGLE POINTER
Presentation TypeDIAL
Illumination Color Generation MethodWHITE SOURCE
Frequency Rating400.0 HERTZ NOMINAL
Pointer PurposeTEMPERATURE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL D — Destroy Item
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 2
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6685-00-842-4980 POSSIBLE MATCH
INDICATOR,TEMPERATURE,THERMOCOUP
Possible match (shared part number)
6685-00-866-1773 POSSIBLE MATCH
INDICATOR,TEMPERATURE,THERMOCOUP
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
8DJ100WAD5 5/9 Secondary reference
General Electric Co Instrument Products Section
EHU9A 4/1 Identification reference
U.S. Government activity
8DJ100WAD3 5/9 Secondary reference
General Electric Co Instrument Products Section
MILI27192 4/1 Identification reference
U.S. Government activity
8DJ100WAD2 3/2 Design control — primary reference
U.S. Government activity
Related Parts
6685-00-842-4980POSSIBLE MATCH
INDICATOR,TEMPERATURE,THERMOCOUP
6685-00-866-1773POSSIBLE MATCH
INDICATOR,TEMPERATURE,THERMOCOUP

Frequently Asked Questions

What is NSN 6685-00-780-7787?

NSN 6685-00-780-7787 is a Indicator,temperature,thermocoup, classified under FSC 6685, Pressure, Temperature, and Humidity Measuring and Controlling Instruments. Status: active.

What NSN replaces 6685-00-780-7787?

2 possible matches (shared part number, not a government interchangeability claim): 6685-00-842-4980, 6685-00-866-1773. Verify interchangeability with system specifications before substitution.

What are the specifications of 6685-00-780-7787?

Key specifications for 6685-00-780-7787: Mounting Facility Type and Quantity: 1 PANEL; Length: 7.000 INCHES NOMINAL IN; AC Voltage Rating: 115.0 VOLTS NOMINAL; Current Type: AC. 14 specifications are documented in the U.S. Government catalog.

Is NSN 6685-00-780-7787 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

What is the DEMIL code for NSN 6685-00-780-7787?

NSN 6685-00-780-7787 has DEMIL Code D. Demilitarization may be required before disposal or transfer to non-military entities.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com