The Analyzer Assembly, cataloged under National Stock Number 6680-01-613-9982, is classified within Federal Supply Class 6680 (Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Naval Inventory Control Point Mechanicsburg. Government technical data includes 4 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6680-01-613-9982 |
| Primary Part Number | XMA357-C3282 OXYGEN CLEANCP |
| Item Name | Analyzer Assembly |
| FSC / FSG | 6680 / 66 — Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments |
| Manufacturer | Naval Inventory Control Point Mechanicsburg |
| Status | ACTIVE |
| Voltage in Volts and Current Type | 24.0 DC |
| General Characteristics Item Description | THIS MONITOR USES A HIGH TEMPERATURE DIFFUSION TYPE ZIRCONIA SENSOR THATCAN BE CALIBRATED IN AIR, HAS A RANGE OF 0 TO 25 PERCENT, AND HAS AN ACCURACYOF PLUS OR MINUS 0.1 PERCENT OVER RANGE. IT IS A LOW CURRENT 24 VDC POWERED DEVICE THAT USES AN INTEGRAL CRITICAL ORIFICE WITH MS STRAIGHT THREAD O-RING CONNECTIONS. IT SUPPLIES AN ISOLATED 4-20 MILLIAMP SIGNAL TO THE PLC, WHICH ININ TURN, SHALL DISPLAY THE OXYGEN CONTENT OF THE FLOWING PRODUCT GAS AT ALL TIMES. THE PLC AUTOMATICALLY ADJUSTS VARIOUS OPERATING PARAMETERS TO INSURE THE PRODUCT GAS PURITY, AS INDICATED BY THE MONITOR'S INPUT, DOES NOT EXCEED 0.5 PERCENT OXYGEN. VDC |
| Criticality Code Justification | ZZZY |
| Reference Number Differentiating Characteristics | CLEANING, PACKAGING, AND MARKING IAW MIL-STD-1330D. |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | S |
| Part Number | Manufacturer |
|---|---|
| XMA357-C3282 OXYGEN CLEANCP | Naval Inventory Control Point Mechanicsburg (USA) |
| Reference | Meaning |
|---|---|
| 20583 REV ACP | 5/1 Secondary reference Naval Inventory Control Point Mechanicsburg |
| 20583 REV A | D/9 Drawing number reference only Rix Industries |
| XMA357-C3282 OXYGEN CLEAN | 3/1 Design control — primary reference Rix Industries |
| C3282 REV CCP | 5/1 Secondary reference Naval Inventory Control Point Mechanicsburg |
| C3282 REV C | 5/1 Secondary reference Rix Industries |
NSN 6680-01-613-9982 is a Analyzer Assembly, manufactured by Naval Inventory Control Point Mechanicsburg, classified under FSC 6680, Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments. Status: active.
NSN 6680-01-613-9982 has 1 manufacturer part number on file: XMA357-C3282 OXYGEN CLEANCP (Naval Inventory Control Point Mechanicsburg).
Key specifications for XMA357-C3282 OXYGEN CLEANCP: Overall Height: 14.875 INCHES NOMINAL IN; Voltage in Volts and Current Type: 24.0 DC; General Characteristics Item Description: THIS MONITOR USES A HIGH TEMPERATURE DIFFUSION TYPE ZIRCONIA SENSOR THATCAN BE CALIBRATED IN AIR, HAS A RANGE OF 0 TO 25 PERCENT, AND HAS AN ACCURACYOF PLUS OR MINUS 0.1 PERCENT OVER RANGE. IT IS A LOW CURRENT 24 VDC POWERED DEVICE THAT USES AN INTEGRAL CRITICAL ORIFICE WITH MS STRAIGHT THREAD O-RING CONNECTIONS. IT SUPPLIES AN ISOLATED 4-20 MILLIAMP SIGNAL TO THE PLC, WHICH ININ TURN, SHALL DISPLAY THE OXYGEN CONTENT OF THE FLOWING PRODUCT GAS AT ALL TIMES. THE PLC AUTOMATICALLY ADJUSTS VARIOUS OPERATING PARAMETERS TO INSURE THE PRODUCT GAS PURITY, AS INDICATED BY THE MONITOR'S INPUT, DOES NOT EXCEED 0.5 PERCENT OXYGEN. VDC; Criticality Code Justification: ZZZY. 4 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.