PartsTable TECHNICAL DATA SHEET
NSN 6665-01-515-7846Government record, cited

Radiac Set6665-01-515-7846

NSN 6665-01-515-7846 · NIIN 015157846 · Part number RADCAL 9010
Radcal Corp · FSC 6665 — Hazard-detecting Instruments and Apparatus · FSG 66 — Instruments and Laboratory Equipment · CAGE 4P061
Government record, cited
NSN 6665-01-515-7846 — this item is cataloged by the U.S. Government under National Stock Number 6665-01-515-7846. Manufacturer of record part number: RADCAL 9010.
Also searched as  6665-01-515-7846 · 6665015157846 · NIIN 015157846 · 01-515-7846 · FSC 6665 Hazard-detecting Instruments and Apparatus · CAGE 4P061 · RADCAL 9010
Nearby stock numbers  ·
Features
  • Radiac Set — FSC 6665
  • Indicator Type: VISUAL
  • Supplementary Features: PORM 4 PCT OF READING, PORM 1 DIGIT, PORM 2 TIMES RESOLUTION; REPEATABILITY PORM 1 PCT OF READING, PORM 1 DIGIT, PORM 2 TIMES RESOLUTION; AUTO TEMPERATURE ACCURACY 2 PCT; AUTO PRESSURE ACCURACY 0.2 PCT, PLUS 2 PCT OF REFERENCE PRESSURE-AMBIENT, OPTIONAL SPECIFY OPT-P; ANALOG CAPTURE 0-5 V, 10KHZ, 12 BIT ANALOG TO DIGITAL SIGNAL CAPTURE, 100 USEC AND 1.25 MV RESOLUTION OVER1 SEC; PLAYBACK TO ANALOG OUTPUT; DATA AVAILABLE AT THE RS-232 PORT OR ANLAOG OUT; TIMING 5 MS TO 6.5 SEC WITH 100USEC RESOLUTION WITH PORM 0.05 PCT ACCURACY; EXCLUSIVE OF NON-INVASIVE DETECTOR; INFRARED REMOTE ALLOWS FULL CONTROL FROM UP TO 10 M AWAY, WILL GO THROUGH LEAD GLASS KHz
  • Features Provided: INTERNAL BATTERY ACCOMMODATION
  • Radiation Type and Function: X-RAYS DETECTS
  • Functional Description: MULTIPURPOSE DOSEMETERS
  • Usage Design: X-RAY SERVICE, X-RAY QA AND COMPLIANCE, X-RAY ACCEPTANCE TESTING, INDUSTRIAL APPLICATIONS, MEDICAL AND HEALTH PHYSICS, THERAPY QA, SECONDARY STANDARDS, NUCLEAR APPLICATIONS, RADIOGRAPHY, FLUOROSCOPY, ANGIOGRAPHY, MAMMOGRAPHY; IMAGE INTENSIFIER; PULSED X-RAY; CINE; CT; DENTAL; 137CS; 60CO IRRADIATOR MEASUREMENTS; SURVEY METER CALIBRATION; INDUSTRIAL X-RAY, CABLES UP TO 300 FEET; VERY LOW DOSE RATES AND VERY HIGH DOSE RATE APPLICATIONS, UP TO 107R/HR WITH SPECIAL MODIFICATION FT
  • 1 manufacturer part number on file
Identification
  • NSN: 6665-01-515-7846
  • NIIN: 015157846
  • FSC: 6665 — Hazard-detecting Instruments and Apparatus
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: RADCAL 9010
  • Manufacturer: Radcal Corp
General Description

The Radiac Set, cataloged under National Stock Number 6665-01-515-7846, is classified within Federal Supply Class 6665 (Hazard-detecting Instruments and Apparatus) of the Instruments and Laboratory Equipment group. The manufacturer of record is Radcal Corp. Government technical data includes 6 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6665-01-515-7846
Primary Part NumberRADCAL 9010
Item NameRadiac Set
FSC / FSG6665 / 66 — Hazard-detecting Instruments and Apparatus
ManufacturerRadcal Corp
StatusACTIVE
Indicator TypeVISUAL
Supplementary FeaturesPORM 4 PCT OF READING, PORM 1 DIGIT, PORM 2 TIMES RESOLUTION; REPEATABILITY PORM 1 PCT OF READING, PORM 1 DIGIT, PORM 2 TIMES RESOLUTION; AUTO TEMPERATURE ACCURACY 2 PCT; AUTO PRESSURE ACCURACY 0.2 PCT, PLUS 2 PCT OF REFERENCE PRESSURE-AMBIENT, OPTIONAL SPECIFY OPT-P; ANALOG CAPTURE 0-5 V, 10KHZ, 12 BIT ANALOG TO DIGITAL SIGNAL CAPTURE, 100 USEC AND 1.25 MV RESOLUTION OVER1 SEC; PLAYBACK TO ANALOG OUTPUT; DATA AVAILABLE AT THE RS-232 PORT OR ANLAOG OUT; TIMING 5 MS TO 6.5 SEC WITH 100USEC RESOLUTION WITH PORM 0.05 PCT ACCURACY; EXCLUSIVE OF NON-INVASIVE DETECTOR; INFRARED REMOTE ALLOWS FULL CONTROL FROM UP TO 10 M AWAY, WILL GO THROUGH LEAD GLASS KHz
Features ProvidedINTERNAL BATTERY ACCOMMODATION
Radiation Type and FunctionX-RAYS DETECTS
Functional DescriptionMULTIPURPOSE DOSEMETERS
Usage DesignX-RAY SERVICE, X-RAY QA AND COMPLIANCE, X-RAY ACCEPTANCE TESTING, INDUSTRIAL APPLICATIONS, MEDICAL AND HEALTH PHYSICS, THERAPY QA, SECONDARY STANDARDS, NUCLEAR APPLICATIONS, RADIOGRAPHY, FLUOROSCOPY, ANGIOGRAPHY, MAMMOGRAPHY; IMAGE INTENSIFIER; PULSED X-RAY; CINE; CT; DENTAL; 137CS; 60CO IRRADIATOR MEASUREMENTS; SURVEY METER CALIBRATION; INDUSTRIAL X-RAY, CABLES UP TO 300 FEET; VERY LOW DOSE RATES AND VERY HIGH DOSE RATE APPLICATIONS, UP TO 107R/HR WITH SPECIAL MODIFICATION FT
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
RADCAL 9010 PRIMARY Radcal Corp (USA)
No interchangeability data on file.
Other items in FSC 6665 — Hazard-detecting Instruments and Apparatus
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6665-00-001-2316
6665-00-001-2316 · Item name not on file
6665-00-001-5355
RADIACMETER
6665-00-006-0951
6665-00-006-0951 · Item name not on file
6665-00-007-6584
6665-00-007-6584 · Item name not on file
6665-00-008-8883
6665-00-008-8883 · Item name not on file
6665-00-009-9478
COUNTER,RATEMETER
6665-00-009-9492
RADIACMETER
6665-00-010-0061
6665-00-010-0061 · Item name not on file

Frequently Asked Questions

What is NSN 6665-01-515-7846?

NSN 6665-01-515-7846 is a Radiac Set, manufactured by Radcal Corp, classified under FSC 6665, Hazard-detecting Instruments and Apparatus. Status: active.

What part numbers are listed for NSN 6665-01-515-7846?

NSN 6665-01-515-7846 has 1 manufacturer part number on file: RADCAL 9010 (Radcal Corp).

What are the specifications of RADCAL 9010?

Key specifications for RADCAL 9010: Indicator Type: VISUAL; Supplementary Features: PORM 4 PCT OF READING, PORM 1 DIGIT, PORM 2 TIMES RESOLUTION; REPEATABILITY PORM 1 PCT OF READING, PORM 1 DIGIT, PORM 2 TIMES RESOLUTION; AUTO TEMPERATURE ACCURACY 2 PCT; AUTO PRESSURE ACCURACY 0.2 PCT, PLUS 2 PCT OF REFERENCE PRESSURE-AMBIENT, OPTIONAL SPECIFY OPT-P; ANALOG CAPTURE 0-5 V, 10KHZ, 12 BIT ANALOG TO DIGITAL SIGNAL CAPTURE, 100 USEC AND 1.25 MV RESOLUTION OVER1 SEC; PLAYBACK TO ANALOG OUTPUT; DATA AVAILABLE AT THE RS-232 PORT OR ANLAOG OUT; TIMING 5 MS TO 6.5 SEC WITH 100USEC RESOLUTION WITH PORM 0.05 PCT ACCURACY; EXCLUSIVE OF NON-INVASIVE DETECTOR; INFRARED REMOTE ALLOWS FULL CONTROL FROM UP TO 10 M AWAY, WILL GO THROUGH LEAD GLASS KHz; Features Provided: INTERNAL BATTERY ACCOMMODATION; Radiation Type and Function: X-RAYS DETECTS. 6 specifications are documented in the U.S. Government catalog.

Is NSN 6665-01-515-7846 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com