PartsTable TECHNICAL DATA SHEET
NSN 6665-01-511-7321Government record, cited

Dosemeter, Personal6665-01-511-7321

NSN 6665-01-511-7321 · NIIN 015117321 · Part number 430211039
Thermo Eberline Llc Div Measurement Control and Sample Identification · FSC 6665 — Hazard-detecting Instruments and Apparatus · FSG 66 — Instruments and Laboratory Equipment · CAGE 52GB6
Government record, cited
NSN 6665-01-511-7321 — this item is cataloged by the U.S. Government under National Stock Number 6665-01-511-7321. Manufacturer of record part number: 430211039.
Also searched as  6665-01-511-7321 · 6665015117321 · NIIN 015117321 · 01-511-7321 · FSC 6665 Hazard-detecting Instruments and Apparatus · CAGE 52GB6 · 430211039 · EPD-N002 · EPD/1/62921/420 · 19-165-939 · EPD-1-45493-420 · 03-1289
Nearby stock numbers  ·
Features
  • Dosemeter,personal — FSC 6665
  • 1 manufacturer part number on file
  • Manufacturer of record: Thermo Eberline Llc Div Measurement Control and Sample Identification
Identification
  • NSN: 6665-01-511-7321
  • NIIN: 015117321
  • FSC: 6665 — Hazard-detecting Instruments and Apparatus
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: 430211039
  • Manufacturer: Thermo Eberline Llc Div Measurement Control and Sample Identification
General Description

The Dosemeter,personal, cataloged under National Stock Number 6665-01-511-7321, is classified within Federal Supply Class 6665 (Hazard-detecting Instruments and Apparatus) of the Instruments and Laboratory Equipment group. The manufacturer of record is Thermo Eberline Llc Div Measurement Control and Sample Identification. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6665-01-511-7321
Primary Part Number430211039
Item NameDosemeter,personal
FSC / FSG6665 / 66 — Hazard-detecting Instruments and Apparatus
ManufacturerThermo Eberline Llc Div Measurement Control and Sample Identification
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
430211039 PRIMARY Thermo Eberline Llc Div Measurement Control and Sample Identification (USA)
Reference documents
ReferenceMeaning
EPD-N002 5/9 Secondary reference
Thermo Eberline Llc Dba Thermo Fisher Scientific Div Thermo Fisher Scientific
EPD/1/62921/420 3/9 Design control — primary reference
Thermo Eberline Llc Div Measurement Control and Sample Identification
19-165-939 5/9 Secondary reference
Fisher Scientific Company L.l.c.
EPD-1-45493-420 5/9 Secondary reference
Thermo Eberline Llc Dba Thermo Fisher Scientific Div Thermo Fisher Scientific
03-1289 5/1 Secondary reference
U.S. Government activity
6665NCM031021 5/1 Secondary reference
Defense Medical Standardization Board
No interchangeability data on file.
Other items in FSC 6665 — Hazard-detecting Instruments and Apparatus
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6665-00-001-2316
6665-00-001-2316 · Item name not on file
6665-00-001-5355
RADIACMETER
6665-00-006-0951
6665-00-006-0951 · Item name not on file
6665-00-007-6584
6665-00-007-6584 · Item name not on file
6665-00-008-8883
6665-00-008-8883 · Item name not on file
6665-00-009-9478
COUNTER,RATEMETER
6665-00-009-9492
RADIACMETER
6665-00-010-0061
6665-00-010-0061 · Item name not on file

Frequently Asked Questions

What is NSN 6665-01-511-7321?

NSN 6665-01-511-7321 is a Dosemeter,personal, manufactured by Thermo Eberline Llc Div Measurement Control and Sample Identification, classified under FSC 6665, Hazard-detecting Instruments and Apparatus. Status: active.

What part numbers are listed for NSN 6665-01-511-7321?

NSN 6665-01-511-7321 has 1 manufacturer part number on file: 430211039 (Thermo Eberline Llc Div Measurement Control and Sample Identification).

What are the specifications of 430211039?

Key specifications for 430211039: Overall Height: 0.800 INCHES NOMINAL IN; Overall Length: 3.300 INCHES NOMINAL IN; Overall Width: 2.500 INCHES NOMINAL IN; Special Features: DESIGNED FOR REAL-TIME DOSE CONTROL WHERE NEURTONS ARE PRESENT; HAS 2 NEUTRONS AND RUNS MORE ADVANCED THAN THE EPD-N1; PROVIDES SEPARATE, SIMULANEOUS MEASUREMENTS AND HAS PROGRAMMABLE ALARMS FOR PHOTON AND NEUTRON DOSES AND DOSE RATE; APPLICATIONS INCLUDE: DOSE CONTROL IN NULEAR REACTOR OPERATION; ROUTINE PHOTON DOSIMETRY FOR PERSONNEL WORKING WITH FISSILE MATERIAL; POST-ACCIDENT DOSIMETRY IN NUCLEAR INSTALLATIONS; POWER SUPPLY IS A SINGLE AA BATTERY, 1.5V ALKALINE CELL FOR CONTINUOUS OPERATION; INCLUDES HIGH IMPACT CASE V. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6665-01-511-7321 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com