PartsTable TECHNICAL DATA SHEET
NSN 6665-01-508-1296Government record, cited

System, Headspace Sampling6665-01-508-1296

NSN 6665-01-508-1296 · NIIN 015081296 · Part number 931-205-G1
Inficon Inc Dba Inficon Inc Div Iss · FSC 6665 — Hazard-detecting Instruments and Apparatus · FSG 66 — Instruments and Laboratory Equipment · CAGE 56507
Government record, cited
NSN 6665-01-508-1296 — this item is cataloged by the U.S. Government under National Stock Number 6665-01-508-1296. Manufacturer of record part number: 931-205-G1.
Also searched as  6665-01-508-1296 · 6665015081296 · NIIN 015081296 · 01-508-1296 · FSC 6665 Hazard-detecting Instruments and Apparatus · CAGE 56507 · 931-205-G1 · 03-0700 · LAP-000116 · 16412-A · 6515NCM030251 · 931-205-G2
Nearby stock numbers  ·
Features
  • System,headspace Sampling — FSC 6665
  • 3 manufacturer part numbers on file
  • Manufacturer of record: Inficon Inc Dba Inficon Inc Div Iss
Identification
  • NSN: 6665-01-508-1296
  • NIIN: 015081296
  • FSC: 6665 — Hazard-detecting Instruments and Apparatus
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: 931-205-G1
  • Manufacturer: Inficon Inc Dba Inficon Inc Div Iss
General Description

The System,headspace Sampling, cataloged under National Stock Number 6665-01-508-1296, is classified within Federal Supply Class 6665 (Hazard-detecting Instruments and Apparatus) of the Instruments and Laboratory Equipment group. The manufacturer of record is Inficon Inc Dba Inficon Inc Div Iss. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6665-01-508-1296
Primary Part Number931-205-G1
Item NameSystem,headspace Sampling
FSC / FSG6665 / 66 — Hazard-detecting Instruments and Apparatus
ManufacturerInficon Inc Dba Inficon Inc Div Iss
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
LAP-000116 Leidos Australia Pty Limited (AUS)
16412-A Smiths Detection-Watford Limited (GBR)
931-205-G1 PRIMARY Inficon Inc Dba Inficon Inc Div Iss (USA)
Reference documents
ReferenceMeaning
03-0700 5/1 Secondary reference
U.S. Government activity
6515NCM030251 5/1 Secondary reference
Defense Medical Standardization Board
931-205-G2 5/1 Secondary reference
Inficon Inc Dba Inficon Inc Div Iss
No interchangeability data on file.
Other items in FSC 6665 — Hazard-detecting Instruments and Apparatus
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6665-00-001-2316
6665-00-001-2316 · Item name not on file
6665-00-001-5355
RADIACMETER
6665-00-006-0951
6665-00-006-0951 · Item name not on file
6665-00-007-6584
6665-00-007-6584 · Item name not on file
6665-00-008-8883
6665-00-008-8883 · Item name not on file
6665-00-009-9478
COUNTER,RATEMETER
6665-00-009-9492
RADIACMETER
6665-00-010-0061
6665-00-010-0061 · Item name not on file

Frequently Asked Questions

What is NSN 6665-01-508-1296?

NSN 6665-01-508-1296 is a System,headspace Sampling, manufactured by Inficon Inc Dba Inficon Inc Div Iss, classified under FSC 6665, Hazard-detecting Instruments and Apparatus. Status: active.

What part numbers are listed for NSN 6665-01-508-1296?

NSN 6665-01-508-1296 has 3 manufacturer part numbers on file: LAP-000116 (Leidos Australia Pty Limited), 16412-A (Smiths Detection-Watford Limited), 931-205-G1 (Inficon Inc Dba Inficon Inc Div Iss).

What are the specifications of 931-205-G1?

Key specifications for 931-205-G1: Overall Height: 7.500 INCHES NOMINAL IN; Overall Length: 15.500 INCHES NOMINAL IN; Overall Width: 14.000 INCHES NOMINAL IN; Special Features: BATTERY OPERATED HEADSPACE SAMPLER FOR FIELD USE; CONVENIENT INLET SYSTEM FOR ANALYZING SOIL, WATER, AND SOLID SAMPLES; INTEGRATED WITH THE HAPSITE DATA SYSTEM; MODULAR, LOW-MAINTENANCE DESIGN FOR RUGGED ENVIRONMENTS; 24-VOLTS, 30 WATTS; THIS SYSTEM ENHANCES THE CAPABILITIES OF THE HAPSITE PORTABLE GAS CHROMATOGRAPH/MASS SPECTROMETER. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6665-01-508-1296 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com