PartsTable TECHNICAL DATA SHEET
NSN 6665-01-368-6290Government record, cited

Detector, Gas6665-01-368-6290

NSN 6665-01-368-6290 · NIIN 013686290 · Part number 6733191
Draeger Inc · FSC 6665 — Hazard-detecting Instruments and Apparatus · FSG 66 — Instruments and Laboratory Equipment · CAGE 6L622
Government record, cited
NSN 6665-01-368-6290 — this item is cataloged by the U.S. Government under National Stock Number 6665-01-368-6290. Manufacturer of record part number: 6733191.
Also searched as  6665-01-368-6290 · 6665013686290 · NIIN 013686290 · 01-368-6290 · FSC 6665 Hazard-detecting Instruments and Apparatus · CAGE 6L622 · 6733191 · 92-10-13-58 · 800-33191 · F92I146 · 5422
Nearby stock numbers  ·
Features
  • Detector,gas — FSC 6665
  • Detecting Element Type: CHEMICAL REACTION
  • Material: GLASS CASE
  • 3 manufacturer part numbers on file
  • Manufacturer of record: Draeger Inc
Identification
  • NSN: 6665-01-368-6290
  • NIIN: 013686290
  • FSC: 6665 — Hazard-detecting Instruments and Apparatus
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: 6733191
  • Manufacturer: Draeger Inc
General Description

The Detector,gas, cataloged under National Stock Number 6665-01-368-6290, is classified within Federal Supply Class 6665 (Hazard-detecting Instruments and Apparatus) of the Instruments and Laboratory Equipment group. The manufacturer of record is Draeger Inc. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6665-01-368-6290
Primary Part Number6733191
Item NameDetector,gas
FSC / FSG6665 / 66 — Hazard-detecting Instruments and Apparatus
ManufacturerDraeger Inc
StatusACTIVE
Detecting Element TypeCHEMICAL REACTION
MaterialGLASS CASE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5120-01-399-9774J5422 POSSIBLE MATCH
SOCKET,SOCKET WRENCH
Possible match (shared part number)The Stanley Works Dba Stanley Proto
Cross-Reference Index
Part NumberManufacturer
800-33191 Skc Inc (USA)
5422 Ghc Specialty Brands, Llc Dba Lab Safety Supply (USA)
6733191 PRIMARY Draeger Inc (USA)
Reference documents
ReferenceMeaning
92-10-13-58 5/1 Secondary reference
Air Force Medical Logistics Office
6733191 3/9 Design control — primary reference
Draeger Safety, Inc.
F92I146 5/1 Secondary reference
Air Force Medical Logistics Office
DIFFUSION TUBE 5/9 Secondary reference
Draeger Safety, Inc.
Related Parts
5120-01-399-9774POSSIBLE MATCH
SOCKET,SOCKET WRENCH
J5422

Frequently Asked Questions

What is NSN 6665-01-368-6290?

NSN 6665-01-368-6290 is a Detector,gas, manufactured by Draeger Inc, classified under FSC 6665, Hazard-detecting Instruments and Apparatus. Status: active.

What part numbers are listed for NSN 6665-01-368-6290?

NSN 6665-01-368-6290 has 3 manufacturer part numbers on file: 800-33191 (Skc Inc), 5422 (Ghc Specialty Brands, Llc Dba Lab Safety Supply), 6733191 (Draeger Inc).

What NSN replaces 6665-01-368-6290?

1 possible match (shared part number, not a government interchangeability claim): 5120-01-399-9774. Verify interchangeability with system specifications before substitution.

What are the specifications of 6733191?

Key specifications for 6733191: Detecting Element Type: CHEMICAL REACTION; Special Features: COLOR DIFFUSION TUBE; MEASURES CARBON MONOXIDE LEVELS 50 TO 600 PPM; CALIBRATED SCALE PRINTED DIRECTLY ON TUBE; RANGE OF MEASUREMENT FOR MAXIMUM PEROID OF USE (8 HOURS) IS 6.3-75 PPM; USED FOR PERSONAL MONITORING TO MEASURE TIME-WEIGHTED AVERAGE CONCENTRATIONS FOR UP TO 8 HOURS; UNIT PKG QTY 10; Part Name Assigned by Controlling Agency: DETECTOR GAS CHEMICAL REACTION COLOR DIFFUSION TUBE 10S; End Item Identification: DIFFUSION TUBE HOLDER,NATIONAL DRAEGER,INC.,P/N 6733014. 2 specifications are documented in the U.S. Government catalog.

Is NSN 6665-01-368-6290 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com