The Radiac Set, cataloged under National Stock Number 6665-00-960-1288, is classified within Federal Supply Class 6665 (Hazard-detecting Instruments and Apparatus) of the Instruments and Laboratory Equipment group. The manufacturer of record is Thermo Eberline Llc Dba Thermo Fisher Scientific Div Thermo Fisher Scientific. Government technical data includes 7 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6665-00-960-1288 |
| Primary Part Number | PAC1S1 |
| Item Name | Radiac Set |
| FSC / FSG | 6665 / 66 — Hazard-detecting Instruments and Apparatus |
| Manufacturer | Thermo Eberline Llc Dba Thermo Fisher Scientific Div Thermo Fisher Scientific |
| Status | ACTIVE |
| Indicator Type | METER |
| Voltage in Volts and Current Type | 6.75 DC AND 8.01 DC |
| Accuracy in Percent | -20.0 TO 20.0 ALL RANGES |
| Detecting Element Type | SCINTILLATION |
| Features Provided | INTERNAL BATTERY ACCOMMODATION |
| Radiation Type and Function | ALPHA RAYS MEASURES |
| Furnished Items | BATTERY,WET CELL,BATTERY,MERCURY,CABLE ASSY,CASE,COUNTER CASE ASSY,ELERONIC ASSY,PROBE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL F — Mutilate — Cut |
| Hazard | Hazardous per DLA record (HMIC Y) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| PAC1S1 PRIMARY | Thermo Eberline Llc Dba Thermo Fisher Scientific Div Thermo Fisher Scientific (USA) |
NSN 6665-00-960-1288 is a Radiac Set, manufactured by Thermo Eberline Llc Dba Thermo Fisher Scientific Div Thermo Fisher Scientific, classified under FSC 6665, Hazard-detecting Instruments and Apparatus. Status: active.
NSN 6665-00-960-1288 has 1 manufacturer part number on file: PAC1S1 (Thermo Eberline Llc Dba Thermo Fisher Scientific Div Thermo Fisher Scientific).
Key specifications for PAC1S1: Indicator Type: METER; Voltage in Volts and Current Type: 6.75 DC AND 8.01 DC; Accuracy in Percent: -20.0 TO 20.0 ALL RANGES; Detecting Element Type: SCINTILLATION. 7 specifications are documented in the U.S. Government catalog.
Hazardous per DLA record (HMIC Y). Hazard information on this page is shown exactly as it appears in the DLA record.
NSN 6665-00-960-1288 has DEMIL Code F. Demilitarization may be required before disposal or transfer to non-military entities.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.