PartsTable TECHNICAL DATA SHEET
NSN 6640-01-694-4151Government record, cited

Centrifuge, Laboratory6640-01-694-4151

NSN 6640-01-694-4151 · NIIN 016944151 · Part number 76181-190
Vwr International Llc Dba Vwr International, Inc · FSC 6640 — Laboratory Equipment and Supplies · FSG 66 — Instruments and Laboratory Equipment · CAGE 01MX7
Government record, cited
NSN 6640-01-694-4151 — this item is cataloged by the U.S. Government under National Stock Number 6640-01-694-4151. Manufacturer of record part number: 76181-190.
Also searched as  6640-01-694-4151 · 6640016944151 · NIIN 016944151 · 01-694-4151 · FSC 6640 Laboratory Equipment and Supplies · CAGE 01MX7 · 76181-190 · 1592637 · 6640NCM216998
Nearby stock numbers  ·
Features
  • Centrifuge,laboratory — FSC 6640
  • Maximum Speed Rating in RPM: 4000.0
  • Operation Method: ELECTRIC
  • Separation Unit Type: ROTOR
  • 1 manufacturer part number on file
  • Manufacturer of record: Vwr International Llc Dba Vwr International, Inc
Identification
  • NSN: 6640-01-694-4151
  • NIIN: 016944151
  • FSC: 6640 — Laboratory Equipment and Supplies
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: 76181-190
  • Manufacturer: Vwr International Llc Dba Vwr International, Inc
General Description

The Centrifuge,laboratory, cataloged under National Stock Number 6640-01-694-4151, is classified within Federal Supply Class 6640 (Laboratory Equipment and Supplies) of the Instruments and Laboratory Equipment group. The manufacturer of record is Vwr International Llc Dba Vwr International, Inc. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6640-01-694-4151
Primary Part Number76181-190
Item NameCentrifuge,laboratory
FSC / FSG6640 / 66 — Laboratory Equipment and Supplies
ManufacturerVwr International Llc Dba Vwr International, Inc
StatusACTIVE
Maximum Speed Rating in RPM4000.0
Operation MethodELECTRIC
Separation Unit TypeROTOR
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
76181-190 PRIMARY Vwr International Llc Dba Vwr International, Inc (USA)
Reference documents
ReferenceMeaning
1592637 5/1 Secondary reference
U.S. Government activity
6640NCM216998 5/1 Secondary reference
Defense Medical Standardization Board
No interchangeability data on file.
Other items in FSC 6640 — Laboratory Equipment and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6640-00-001-3348
6640-00-001-3348 · Item name not on file
6640-00-001-6670
LID,ANAEROBIC CULTURE APPARATUS
6640-00-001-6868
CONTROLLER,TIME AND TEMPERATURE,
6640-00-001-6871
6640-00-001-6871 · Item name not on file
6640-00-001-8928
6640-00-001-8928 · Item name not on file
6640-00-001-9167
6640-00-001-9167 · Item name not on file
6640-00-001-9168
6640-00-001-9168 · Item name not on file
6640-00-003-4362
6640-00-003-4362 · Item name not on file

Frequently Asked Questions

What is NSN 6640-01-694-4151?

NSN 6640-01-694-4151 is a Centrifuge,laboratory, manufactured by Vwr International Llc Dba Vwr International, Inc, classified under FSC 6640, Laboratory Equipment and Supplies. Status: active.

What part numbers are listed for NSN 6640-01-694-4151?

NSN 6640-01-694-4151 has 1 manufacturer part number on file: 76181-190 (Vwr International Llc Dba Vwr International, Inc).

What are the specifications of 76181-190?

Key specifications for 76181-190: Maximum Speed Rating in RPM: 4000.0; Special Features: CENTRIFUGE,LABORATORY, BENCHTOP, ACCEPTS ALL COMMON TUBE SIZES UP TO 50 ML, DIGITAL SPEED CONTROL, SPINS UP TO 4000 RPM/2850 XG, LCD DISPLAY, MICROPROCESSOR CONTROL, IMBALANCE SENSOR, INTEGRATED SAFETY LID-LOCK, DESIGNED TO ACCEPT UP TO 6 INTERCHANGEABLE ROTORS. RPM; Part Name Assigned by Controlling Agency: CENTRIFUGE,LABORATORY, BENCHTOP; Operation Method: ELECTRIC. 3 specifications are documented in the U.S. Government catalog.

Is NSN 6640-01-694-4151 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com